2.2 | 1 | **Description**: Learn how to identify the Auto-Light X0 mains connection, X1 safety and production interface, and X2 axis interface. The pin assignments and diagrams are reproduced from the supplied operating manual in English. |
| 2 | |||
| 3 | (% class="box errormessage" %) | ||
| 4 | ((( | ||
| 5 | **Qualified integration work only: **The manual diagrams are connection examples, not a complete safety design or permission to wire an energised system. An appropriately qualified integrator must design, calculate, isolate, wire, validate, and document the complete safety-related control system for the delivered machine. | ||
| 6 | ))) | ||
| 7 | |||
| 8 | ---- | ||
| 9 | |||
| 10 | = Connection Locations = | ||
| 11 | |||
| 12 | X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement. | ||
| 13 | |||
| |
3.2 | 14 | [[image:1788847354911-289.png]] |
| |
3.3 | 15 | |
| |
2.2 | 16 | |
| |
3.3 | 17 | = X0 Mains Supply = |
| 18 | |||
| 19 | The manual identifies X0 as a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation. | ||
| 20 | |||
| 21 | (% class="box warningmessage" %) | ||
| 22 | ((( | ||
| 23 | **Keep X0 separate from model consumption data: **The X0 declaration is the documented supply-interface value. The lower power-consumption figures listed for individual laser-source variants in Technical Specifications do not replace the delivered supply and protection requirements. | ||
| 24 | ))) | ||
| 25 | |||
| |
5.2 | 26 | |
| 27 | = X1 Laser Interface - Pin Assignment = | ||
| 28 | |||
| 29 | (% class="table-condensed table-striped" %) | ||
| 30 | |**Pin(s)**|**Signal**|**Manual description / use** | ||
| 31 | |1-2|Emergency-stop circuit 1|External wiring through a safety module required | ||
| 32 | |3-4|Emergency-stop circuit 2|External wiring through a safety module required | ||
| 33 | |5-6|Emergency-stop acknowledgement|Acknowledgement contact | ||
| 34 | |7-8|Shutter circuit 1|External wiring through a safety module required | ||
| 35 | |9-10|Shutter circuit 2|External wiring through a safety module required | ||
| 36 | |11-12|Shutter acknowledgement|Acknowledgement contact | ||
| 37 | |13|+24 V|Supply voltage for inputs | ||
| 38 | |14|External START|24 V input | ||
| 39 | |15|External STOP|24 V input | ||
| 40 | |16|Emergency-stop status|24 V output | ||
| 41 | |17|SHUTTER status|24 V output | ||
| 42 | |18|LASER READY status|24 V output | ||
| 43 | |19|LASER BUSY status|24 V output | ||
| 44 | |20|LASER END status|24 V output | ||
| 45 | |21-22|Inputs 4 and 5|24 V inputs | ||
| 46 | |23-24|Outputs 4 and 5|24 V outputs | ||
| 47 | |25|GND|Ground for outputs | ||
| 48 | |||
| 49 | |||
| 50 | |||
| 51 | = X1 Emergency-Stop Connection Examples = | ||
| 52 | |||
| 53 | The manual example routes two external emergency-stop channels through a safety module. Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine. | ||
| 54 | |||
| 55 | [[**Example: dual emergency-stop circuits at X1.1-X1.4.**>>image:1788848413333-368.png]] | ||
| 56 | |||
| 57 | |||
| 58 | Emergency-stop acknowledgement is provided at X1.5/X1.6. TAcknowledgement is required at every restart of the system and after every operation of the emergency stop. | ||
| 59 | |||