Auto-Light Interfaces and Connection Examples
Description: Learn how to identify the Auto-Light X0 mains connection, X1 safety and production interface, and X2 axis interface. The pin assignments and diagrams are reproduced from the supplied operating manual in English.
- Connection Locations
- X0 Mains Supply
- X1 Laser Interface - Pin Assignment
- X1 Emergency-Stop Connection Examples
- X1 Shutter Connection Examples
- X1 External Inputs
- X1 External Outputs
- X2 Axes Interface - 25-pin Sub-D Plug
- X2 Functional Grouping
- Integration and Commissioning Checks
Connection Locations
X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.

Auto-Light front and rear rack panels. X1 and X2 are located on the rear panel.
X0 Mains Supply
X0 is a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
X1 Laser Interface - Pin Assignment
| Pin(s) | Signal | Manual description / use |
| 1-2 | Emergency-stop circuit 1 | External wiring through a safety module required |
| 3-4 | Emergency-stop circuit 2 | External wiring through a safety module required |
| 5-6 | Emergency-stop acknowledgement | Acknowledgement contact |
| 7-8 | Shutter circuit 1 | External wiring through a safety module required |
| 9-10 | Shutter circuit 2 | External wiring through a safety module required |
| 11-12 | Shutter acknowledgement | Acknowledgement contact |
| 13 | +24 V | Supply voltage for inputs |
| 14 | External START | 24 V input |
| 15 | External STOP | 24 V input |
| 16 | Emergency-stop status | 24 V output |
| 17 | SHUTTER status | 24 V output |
| 18 | LASER READY status | 24 V output |
| 19 | LASER BUSY status | 24 V output |
| 20 | LASER END status | 24 V output |
| 21-22 | Inputs 4 and 5 | 24 V inputs |
| 23-24 | Outputs 4 and 5 | 24 V outputs |
| 25 | GND | Ground for outputs |
X1 Emergency-Stop Connection Examples
Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine.

Example: dual emergency-stop circuits at X1.1-X1.4.
Emergency-stop acknowledgement is provided at X1.5/X1.6. The source manual states that acknowledgement is required at every restart of the system and after every operation of the emergency stop.

Example: emergency-stop acknowledgement at X1.5/X1.6.
X1 Shutter Connection Examples
The shutter interface also uses two external channels. Circuit 1 uses X1.7/X1.8 and circuit 2 uses X1.9/X1.10. The manual requires the shutter circuit to be interrupted whenever the protective enclosure is opened.

Example: dual shutter circuits at X1.7-X1.10.
Shutter acknowledgement is provided at X1.11/X1.12. A closed and validated shutter circuit enables the laser system's active mode. The source states that laser-energy emission is possible only in active mode; a closed circuit is permission, not a marking command.

Example: shutter acknowledgement at X1.11/X1.12.
X1 External Inputs
The manual states that the X1 inputs are switched using the internal 24 V auxiliary supply at X1.13. Its example closes an external contact between X1.13 and X1.14 to issue External START. X1.15 is External STOP; X1.21 and X1.22 are Inputs 4 and 5.

Example: external input switched from X1.13 to X1.14.
X1 External Outputs
The source states that an active output supplies 24 V and is used with output ground at X1.25. The maximum output current is 250 mA. Status outputs are X1.16-X1.20; assignable Outputs 4 and 5 are X1.23/X1.24.

External-output example. Confirm the selected output and load connection against the delivered electrical drawing.
X2 Axes Interface - 25-pin Sub-D Plug
X2 provides direction and step outputs for X, Y, Z, and R axes, zero signals, GND, and a documented +5 V supply. The image below reproduces the complete English pin table from the manual translation.
| Pin | Direction | Description |
|---|---|---|
| 1 | Output | Direction X |
| 2 | Output | Step X |
| 3 | Output | Direction Y |
| 4 | Output | Step Y |
| 5 | Output | Direction Z |
| 6 | Output | Step Z |
| 7 | Output | Direction R |
| 8 | Output | Step R |
| 9 | Output | Zero X |
| 10 | - | Not connected |
| 11 | Input | Zero Y |
| 12 | - | Not connected |
| 13 | Input | Zero Z |
| 14 | - | Not connected |
| 15 | Input | Zero R |
| 16 | - | Not connected |
| 17 | Output | GND |
| 18 | - | Not connected |
| 19 | Output | +5V supply |
| 20 | - | Not connected |
| 21 | - | Not connected |
| 22 | - | Not connected |
| 23 | - | Not connected |
| 24 | - | Not connected |
| 25 | - | Not connected |
X2 Functional Grouping
| Axis / function | Pin(s) | Direction stated in manual |
| X axis | 1 Direction; 2 Step; 9 Zero | Outputs on all three pins, as stated |
| Y axis | 3 Direction; 4 Step; 11 Zero | Direction/Step outputs; Zero input |
| Z axis | 5 Direction; 6 Step; 13 Zero | Direction/Step outputs; Zero input |
| R axis | 7 Direction; 8 Step; 15 Zero | Direction/Step outputs; Zero input |
| Reference | 17 GND; 19 +5 V | Outputs, as stated |
| Not connected | 10, 12, 14, 16, 18, 20-25 | NC |
Integration and Commissioning Checks
Confirm X1 is a 25-pin Sub-D socket and X2 is a 25-pin Sub-D plug before preparing mating connectors.
- Keep safety functions, production commands, status monitoring, axis signals, and workstation connections identified separately in the electrical documentation.
- Verify conductor identification, shielding, routing, protective bonding, connector retention, strain relief, and separation from interference sources for the delivered installation.
- Validate both emergency-stop channels, both shutter channels, acknowledgement behavior, guard opening, status outputs, and prevention of unexpected restart before laser operation is released.
- Confirm the External START/STOP logic and LASER READY/BUSY/END sequence against the host control specification without bypassing any safety permission.
- For every installed axis, verify direction, step scaling, travel limits, zero/reference behavior, and safe motion before placing a workpiece in the marking area.
- Document measured results and obtain the required approval for the complete integrated machine, not only the Auto-Light rack.