Description: Learn how to identify the Auto-Light X0 mains connection, X1 safety and production interface, and X2 axis interface. The pin assignments and diagrams are reproduced from the supplied operating manual in English.
Connection Locations
X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.

X0 Mains Supply
The manual identifies X0 as a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
X1 Laser Interface - Pin Assignment
| Pin(s) | Signal | Manual description / use |
| 1-2 | Emergency-stop circuit 1 | External wiring through a safety module required |
| 3-4 | Emergency-stop circuit 2 | External wiring through a safety module required |
| 5-6 | Emergency-stop acknowledgement | Acknowledgement contact |
| 7-8 | Shutter circuit 1 | External wiring through a safety module required |
| 9-10 | Shutter circuit 2 | External wiring through a safety module required |
| 11-12 | Shutter acknowledgement | Acknowledgement contact |
| 13 | +24 V | Supply voltage for inputs |
| 14 | External START | 24 V input |
| 15 | External STOP | 24 V input |
| 16 | Emergency-stop status | 24 V output |
| 17 | SHUTTER status | 24 V output |
| 18 | LASER READY status | 24 V output |
| 19 | LASER BUSY status | 24 V output |
| 20 | LASER END status | 24 V output |
| 21-22 | Inputs 4 and 5 | 24 V inputs |
| 23-24 | Outputs 4 and 5 | 24 V outputs |
| 25 | GND | Ground for outputs |
X1 Emergency-Stop Connection Examples
The manual example routes two external emergency-stop channels through a safety module. Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine.

Example: dual emergency-stop circuits at X1.1-X1.4.
Emergency-stop acknowledgement is provided at X1.5/X1.6. TAcknowledgement is required at every restart of the system and after every operation of the emergency stop.