Spare Parts and Consumables

Version 1.9 by jadomatis on 2026/09/02 11:09

Use only spare parts, consumables, cleaning materials, and replacement components approved for the installed High-Light configuration.

Incorrect or incompatible components can affect marking quality, cooling performance machine reliability, and laser Class 1 protection.

Consumable Items

The High-Light may require the following consumables during normal operation and maintenance:

Ventilation Filter Mats

Filter mats protect the laser source, electronics, and computer components against dust and contamination in the cooling air.

  • Inspect the ventilation area monthly.
  • Replace heavily contaminated filter mats.
  • Do not operate the system when airflow is restricted.
  • Use the correct filter material and dimensions for the installed High-Light configuration

Extraction Filters

When an extraction system is installed, its filters must be checked and replaced according to the process load and filter condition.

  • Check the pre-filter at least monthly.
  • Replace the pre-filter when it is fully or heavily contaminated.
  • Check the main filter at least annually.
  • Replace the main filter when contaminated or when extraction performance decreases.

Processes that produce large quantities of dust, fumes, or aerosols may require more frequent filter replacement.

Important: Used extraction filters may contain hazardous process residues, Handle and dispose of them according to the processed material and applicable local requirements.

Optical Cleaning Materials

Only suitable optical-cleaning materials may be used on laser lenses and protective glass.

Approved cleaning materials may include:

  • Soft, lint-free optical cloths
  • Lens-cleaning paper
  • Optical lens-cleaning wipes
  • A small manual air blower
  • A manufacturer-approved optical cleaning solution
  • High-purity alcohol of at least 98%, where approved

Never use:

  • Compressed air
  • Paper towels or abrasive cloths
  • Hard tools or scraping instruments
  • Contaminated cleaning cloths
  • Household glass cleaners
  • Unapproved solvents

Apply the cleaning solution to the cloth rather than dipping the cloth into the solution

For complete cleaning instructions, refer to the High-Light Maintenance Article.

Lubricants

The Z-axis spindle should be inspected monthly and cleaned and lubricated when required.

Use only a lubricant approved for the installed axis. Do not allow oil or grease to contact optical components, workpieces, electrical parts, or marking surfaces.

Laser Foil

Laser foil is used to produce high-contrast markings on suitable metal surfaces. Its compatibility must be validated with the installed laser source, material, focus, and marking parameters.

Ablation Film

Ablation film can be marked and cut using a validated laser process before being bonded to the workpiece. Different film colors and material properties may be available.

For more information, refer to Accessories and Options.