Troubleshooting

Version 1.4 by jadomatis on 2026/09/07 11:23

Description: Learn how to identify common Auto-Light symptoms, verify the integration start conditions, and decide whether the fault is within the operator's authority or must be escalated. Auto-Light is a Class 4 integration laser, so the host machine's safeguards are part of every diagnosis.

Safety first: Never bypass a guard, emergency-stop channel, shutter circuit, acknowledgement circuit, emission warning, extraction interlock, or protective cover to test the laser. Maintenance and repair may be performed only by Schilling Marking Systems or authorised personnel in accordance with the site's safety procedure. 


First Response

  1. Stop the marking command. If an unsafe condition exists, operate the host machine's emergency stop and follow the site's isolation procedure.
  2. Keep personnel outside the laser hazard area. Do not open the enclosure until laser emission has stopped and the system is in the approved safe state.
  3. Before resetting anything, record the AnyMarker message, host-controller message, job name, machine state, and the last action performed.
  4. Check the host safety chain: emergency-stop channels, guard or access monitoring, shutter circuits, acknowledgements, emission warning, and extraction readiness.
  5. Check whether the expected X1 status sequence is present: emergency-stop status, SHUTTER, LASER READY, LASER BUSY, and LASER END.

Correct only conditions covered by operator training. If the condition repeats, cannot be identified, or requires electrical, optical, or internal access, isolate the system and contact authorised service personnel. 

Capture the Fault Before Resetting

RecordExample
System and jobAuto-Light serial/model, AnyMarker version, job name, selected device and parameter set
What happenedWould not become ready, stopped during marking, no mark, weak mark, axis fault, or communication loss
Signal stateX1 emergency-stop, SHUTTER, LASER READY, LASER BUSY and LASER END; host guard and extraction states
Timing and evidenceTime, last successful cycle, recent change, error text, and safe photographs or screenshots