Transportation and Installation

Version 1.6 by jadomatis on 2026/09/07 09:29

Description: Learn how to receive, inspect, unpack, move, and install the Auto-Light before commissioning. Apply the same checks after any relocation.

Class 4 integration laser: Transportation and installation may be performed only by qualified personnel. Do not apply power until the Auto-Light and the host machine have been mechanically and electrically installed and all required laser-safety measures are ready for validation.


Delivery Inspection

Inspect the shipment immediately after unloading and before installation:

  • Check the Auto-Light and all supplied components for visible transport damage.
  • Check accessible screws and threaded connections for signs of movement or loosening.
  • Compare the shipment with the order and delivery documents; the actual configuration and options may differ from the manual's standard-configuration list.
  • If anything is damaged or missing, record it in writing, note it on the freight documents, take photographs, and send the report to Schilling Marking Systems.

Protect the optics: Keep the lens-unit or objective protection cover installed until the marking head is in its final installed position. Clean, undamaged optics are required for correct marking performance 

External Transportation

  • Keep the carton upright and firmly secured to the pallet.
  • Secure the palletised shipment against sliding and tipping throughout transport.
  • Use a forklift suitable for the weight and delivered configuration when unloading the palletised carton.
  • Protect the shipment from strong vibration, shock, contamination, and weather exposure.

Unpacking

Two qualified people are required to remove the transport packaging.

  1. Place the carton and pallet upright on level ground using a suitable forklift.
  2. Stabilise the load, then release the black tensioning straps.
  3. Remove the carton and packing sections carefully so that no section tips or falls.
  4. Remove the remaining packaging and transport restraints only when the equipment is supported and ready for installation.
  5. Retain reusable packaging and every delivered transport restraint for future shipment or long-distance relocation.

Handling rule: Keep the Auto-Light upright. Avoid mechanical loads, vibration, and impact; the system contains high-quality electrical and optical components.

In-Plant Transportation

  1. Stop the process and set the rear main switch to 0 (OFF).
  2. Disconnect the electrical supply cable.
  3. Disconnect and remove the extraction system where fitted, following the extraction supplier's instructions.
  4. Keep the equipment upright and slightly lift the supported assembly with handling equipment suitable for its weight and configuration.
  5. Move it without strong vibration or shock and place it on a level, clean installation surface.
  6. After relocation, realign the system, repeat the initial electrical commissioning procedure, and perform a controlled functional test.

Installation-Site Requirements

RequirementInstallation criterion
Environment+15 °C to +35 °C; relative humidity no higher than 90%, non-condensing.
AcclimatisationAfter a major temperature change, allow the equipment to return to room temperature before commissioning.
SupportUpright, level, clean, stable, and suitable for the delivered configuration.
CoolingProvide adequate air to both 19-inch rack units; keep ventilation openings and filter mats unobstructed.
ExtractionProvide extraction suitable for the gases, vapours, aerosols, and dust generated by the material and process.
SafetyComplete the host enclosure, access control, emergency-stop functions, shutter interlocks, emission warning, and other required safeguards.