Description: Learn about the routine Auto-Light operation after the complete machine has been commissioned, validated, and released for production.
Before You Start
Confirm the operating area and machine are ready before switching on:
- Only trained and authorised personnel are present, and nobody can enter the laser hazard zone during operation.
- The approved enclosure is closed and undamaged; access switches, emergency-stop devices, shutter interlocks, and emission warning are ready for use.
- The objective protection cap has been removed, the optics are clean, and the rack ventilation openings and filter mats are unobstructed.
- The workpiece and fixture are stable and positioned for the validated job. Keep loose or reflective objects out of the processing area.
- The approved extraction system is running and suitable for the material and process.
- The correct AnyMarker Designer job, material-specific parameter set, and variable data are available and approved for production.
Start
- Confirm the host machine is in its approved safe start condition and extraction is operating.
- Set the main switch on the rear of the Auto-Light rack to I (ON).
- Turn the laser key switch on the front of the rack to I.
- Start the approved workstation and open AnyMarker Designer.
- Establish communication with the Auto-Light controller. Confirm that the host machine reports LASER READY and that no unresolved fault is active.
- Complete the emergency-stop and shutter acknowledgement required by the validated integration sequence before enabling a production cycle.

Prepare the Job
- Load the approved job and parameter set in AnyMarker Designer.
- Secure the workpiece in the validated fixture and select the required variable data.
- Use the Pilot function to display the marking field without production-laser emission.
- Move or adjust the workpiece until the projected field has the correct position and orientation.
- Set the correct focal distance with the approved Z-axis or focusing method. Incorrect focus is the most common cause of a weak or invisible mark.
- Recheck the job content, position, orientation, focus, parameter set, and variable data before enabling the production cycle.
Run
- Close and secure the approved host-machine enclosure. Confirm that both emergency-stop circuits and both shutter circuits are satisfied and acknowledged as required by the validated safety sequence.
- Start the job using the approved AnyMarker Designer or host-machine production sequence.
- Monitor the integrated machine and the LASER READY, LASER BUSY, LASER END, SHUTTER, and emergency-stop status signals used by the installation.
- Remain at the operating position while the system is powered or processing. Do not leave the laser system unattended.
- If the start condition is lost, allow the laser cell to stop and investigate only after the system is in a safe state.
Quality Check and Adjustment
- Inspect the result for correct content, position, orientation, legibility, contrast, depth, and unwanted thermal effects.
- For a weak or invisible mark, check the Z-axis position and focal distance before changing marking energy.
- Inspect the objective and protective glass if marking quality deteriorates.
- Change parameters only within the qualified process and verify changes on an approved sample before returning to production.
Shutdown
- Finish or stop the current job and confirm that laser emission has ended.
- Save any required production data and close AnyMarker Designer in accordance with the site procedure.
- Set the rear main switch to 0 (OFF).
- The operating manual permits the front key switch to remain at I or be returned to 0. Follow the site's approved key-control and access procedure.
- Keep extraction running until remaining fumes and dust have been removed, then shut it down according to the extraction-system instructions.
- Leave the processing area clean and secure. Switch off the main switch whenever the machine is not in use.
If Something Does Not Work
| Symptom | Check |
| No ready signal | Host safety acknowledgement, emergency-stop circuits, shutter circuits, enclosure status, and active faults. |
| No marking | Safety permission, shutter status, focus, job parameters, connection to the controller, and material suitability. |
| Weak marking | Z-axis position, focal distance, objective cleanliness, protective glass, and the approved parameter set. |
| Unexpected stop | Treat the loss of a start condition as a fault. Secure and isolate the system before investigation. |