Last modified by jadomatis on 2026/09/08 07:54

From version 3.1
edited by jadomatis
on 2026/09/08 07:54
Change comment: There is no comment for this version
To version 2.6
edited by jadomatis
on 2026/09/08 07:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,6 @@
1 1  **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
2 2  
3 -{{toc/}}
3 +/t
4 4  
5 5  (% class="box warningmessage" %)
6 6  (((
... ... @@ -12,7 +12,7 @@
12 12  = System Identification =
13 13  
14 14  (% class="table-condensed table-striped" %)
15 -|**Property**|**Specification**
15 +|**Property**|**Manual specification**
16 16  |System type|Integration laser
17 17  |Laser classification|Laser Class 4
18 18  |Protection rating|IP21
... ... @@ -29,6 +29,8 @@
29 29  
30 30  = Laser-Source Variants =
31 31  
32 +The F models use a pulsed fiber laser. The M models use a pulsed MOPA fiber laser. Values in both tables are reproduced from the manual's data sheet.
33 +
32 32  (% class="table-condensed table-striped" %)
33 33  |**Model**|**Laser source**|**Nominal power**|**Pulse energy**|**Beam quality**
34 34  |F20|Pulsed fiber|20 W|1 mJ|M2 < 1.5
... ... @@ -84,7 +84,7 @@
84 84  |After a major temperature change|Allow the system to return to room temperature before commissioning
85 85  |Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
86 86  |Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 -|Process emissions|Provide extraction suitable for the material, fumes, vapors, dust, and particles produced
89 +|Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
88 88  
89 89  
90 90  
... ... @@ -91,7 +91,7 @@
91 91  = Interfaces and Supply - Overview =
92 92  
93 93  (% class="table-condensed table-striped" %)
94 -|**Connection**|**Description**|**Purpose**
96 +|**Connection**|**Manual description**|**Purpose**
95 95  |X0|230 V / 600 W, including main switch|Mains-supply interface
96 96  |X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
97 97  |X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND