Auto-Light Technical Specifications

Zuletzt geändert von jadomatis am 2026/09/08 07:54

Description: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.

Configuration control: The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.


System Identification

PropertySpecification
System typeIntegration laser
Laser classificationLaser Class 4
Protection ratingIP21
Available variantsF20, F30, F50, M20, and M30
CoolingLow-noise forced air
Sound level< 70 dB

Principal Dimensions

1788844179033-844.png

Auto-Light principal dimensions and standard optical arrangement. Verify mounting and connector details against the delivered drawings.

Laser-Source Variants

ModelLaser sourceNominal powerPulse energyBeam quality
F20Pulsed fiber20 W1 mJM2 < 1.5
F30Pulsed fiber30 W1 mJM2 < 1.5
F50Pulsed fiber50 W1 mJM2 < 1.8
M20Pulsed MOPA fiber20 W0.7 mJM2 < 1.3
M30Pulsed MOPA fiber30 W1 mJM2 < 1.3

Pulse and Electrical Data

ModelWavelengthPulse frequencyPulse durationPower consumption
F201060-1070 nm20-60 kHz100 ns< 200 W
F301060-1070 nm30-60 kHz100 ns< 300 W
F501060-1070 nm50-100 kHz100 ns< 340 W
M201060-1070 nm2-550 kHz2-550 ns< 150 W
M301060-1070 nm2-550 kHz2-550 ns< 170 W

 Do not substitute process settings: These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration.

Common Optical and Mechanical Data

PropertyUnitF20 / F30 / F50 / M20 / M30
Fibre lengthm3
Standard lens-F-Theta, 160 mm focal length
Standard working distancemm176
Standard field sizemm110 x 110
Lens wavelengthnm1064
Laser-rack dimensions (L x W x H)mm550 x 441 x 162
Laser-head dimensionsmm367 x 131 x 131

 Standard optics: The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.

Operating and Installation Conditions

ConditionRequirement
Ambient temperature+15 degrees C to +35 degrees C
Relative humidityNo higher than 90%, non-condensing
After a major temperature changeAllow the system to return to room temperature before commissioning
Cooling-air openingsKeep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
Operating environmentAvoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
Process emissionsProvide extraction suitable for the material, fumes, vapors, dust, and particles produced

Interfaces and Supply - Overview

ConnectionDescriptionPurpose
X0230 V / 600 W, including main switchMains-supply interface
X125-pin Sub-D socketDual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
X1 outputs24 V when active; Imax 250 mAExternal status and assigned production outputs referenced to X1.25 GND
X225-pin Sub-D plugDirection, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
Rack data connectionsUSB, Ethernet, and HDMIWorkstation, network, and display connections according to the delivered integration

 Safety interface: X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel.

Verification Before Use

  • Match the model designation and serial number to the nameplate and order documentation.
  • Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept.
  • Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring.
  • Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards.
  • Record approved deviations or options in the machine technical file and update the applicable KB article when the as-built configuration changes.