Last modified by jadomatis on 2026/09/08 07:54

From version 3.1
edited by jadomatis
on 2026/09/08 07:54
Change comment: There is no comment for this version
To version 2.3
edited by jadomatis
on 2026/09/08 07:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 1  **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
2 2  
3 -{{toc/}}
4 -
5 5  (% class="box warningmessage" %)
6 6  (((
7 7  **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.
... ... @@ -12,7 +12,7 @@
12 12  = System Identification =
13 13  
14 14  (% class="table-condensed table-striped" %)
15 -|**Property**|**Specification**
13 +|**Property**|**Manual specification**
16 16  |System type|Integration laser
17 17  |Laser classification|Laser Class 4
18 18  |Protection rating|IP21
... ... @@ -29,6 +29,8 @@
29 29  
30 30  = Laser-Source Variants =
31 31  
30 +The F models use a pulsed fiber laser. The M models use a pulsed MOPA fiber laser. Values in both tables are reproduced from the manual's data sheet.
31 +
32 32  (% class="table-condensed table-striped" %)
33 33  |**Model**|**Laser source**|**Nominal power**|**Pulse energy**|**Beam quality**
34 34  |F20|Pulsed fiber|20 W|1 mJ|M2 < 1.5
... ... @@ -68,49 +68,4 @@
68 68  |Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162
69 69  |Laser-head dimensions|mm|367 x 131 x 131
70 70  
71 -(% class="box warningmessage" %)
72 -(((
73 - **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
74 -)))
75 -
76 -
77 -
78 -= Operating and Installation Conditions =
79 -
80 -(% class="table-condensed table-striped" %)
81 -|**Condition**|**Requirement**
82 -|Ambient temperature|+15 degrees C to +35 degrees C
83 -|Relative humidity|No higher than 90%, non-condensing
84 -|After a major temperature change|Allow the system to return to room temperature before commissioning
85 -|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
86 -|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 -|Process emissions|Provide extraction suitable for the material, fumes, vapors, dust, and particles produced
88 -
89 -
90 -
91 -= Interfaces and Supply - Overview =
92 -
93 -(% class="table-condensed table-striped" %)
94 -|**Connection**|**Description**|**Purpose**
95 -|X0|230 V / 600 W, including main switch|Mains-supply interface
96 -|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
97 -|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND
98 -|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
99 -|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration
100 -
101 -(% class="box errormessage" %)
102 -(((
103 - **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel.
104 -)))
105 -
106 -
107 -
108 -= Verification Before Use =
109 -
110 -* Match the model designation and serial number to the nameplate and order documentation.
111 -* Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept.
112 -* Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring.
113 -* Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards.
114 -* Record approved deviations or options in the machine technical file and update the applicable KB article when the as-built configuration changes.
115 -
116 116