Änderungen von Dokument Auto-Light Technical Specifications
Zuletzt geändert von jadomatis am 2026/09/08 07:54
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -1,7 +1,5 @@ 1 1 **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants. 2 2 3 -{{toc/}} 4 - 5 5 (% class="box warningmessage" %) 6 6 ((( 7 7 **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values. ... ... @@ -12,7 +12,7 @@ 12 12 = System Identification = 13 13 14 14 (% class="table-condensed table-striped" %) 15 -|**Property**|** Specification**13 +|**Property**|**Manual specification** 16 16 |System type|Integration laser 17 17 |Laser classification|Laser Class 4 18 18 |Protection rating|IP21 ... ... @@ -29,6 +29,8 @@ 29 29 30 30 = Laser-Source Variants = 31 31 30 +The F models use a pulsed fiber laser. The M models use a pulsed MOPA fiber laser. Values in both tables are reproduced from the manual's data sheet. 31 + 32 32 (% class="table-condensed table-striped" %) 33 33 |**Model**|**Laser source**|**Nominal power**|**Pulse energy**|**Beam quality** 34 34 |F20|Pulsed fiber|20 W|1 mJ|M2 < 1.5 ... ... @@ -49,68 +49,4 @@ 49 49 |M20|1060-1070 nm|2-550 kHz|2-550 ns|< 150 W 50 50 |M30|1060-1070 nm|2-550 kHz|2-550 ns|< 170 W 51 51 52 -(% class="box infomessage" %) 53 -((( 54 - **Do not substitute process settings: **These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration. 55 -))) 56 - 57 - 58 - 59 -= Common Optical and Mechanical Data = 60 - 61 -(% class="table-condensed table-striped" %) 62 -|**Property**|**Unit**|**F20 / F30 / F50 / M20 / M30** 63 -|Fibre length|m|3 64 -|Standard lens|-|F-Theta, 160 mm focal length 65 -|Standard working distance|mm|176 66 -|Standard field size|mm|110 x 110 67 -|Lens wavelength|nm|1064 68 -|Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162 69 -|Laser-head dimensions|mm|367 x 131 x 131 70 - 71 -(% class="box warningmessage" %) 72 -((( 73 - **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary. 74 -))) 75 - 76 - 77 - 78 -= Operating and Installation Conditions = 79 - 80 -(% class="table-condensed table-striped" %) 81 -|**Condition**|**Requirement** 82 -|Ambient temperature|+15 degrees C to +35 degrees C 83 -|Relative humidity|No higher than 90%, non-condensing 84 -|After a major temperature change|Allow the system to return to room temperature before commissioning 85 -|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats 86 -|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up 87 -|Process emissions|Provide extraction suitable for the material, fumes, vapors, dust, and particles produced 88 - 89 - 90 - 91 -= Interfaces and Supply - Overview = 92 - 93 -(% class="table-condensed table-striped" %) 94 -|**Connection**|**Description**|**Purpose** 95 -|X0|230 V / 600 W, including main switch|Mains-supply interface 96 -|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O 97 -|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND 98 -|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND 99 -|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration 100 - 101 -(% class="box errormessage" %) 102 -((( 103 - **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel. 104 -))) 105 - 106 - 107 - 108 -= Verification Before Use = 109 - 110 -* Match the model designation and serial number to the nameplate and order documentation. 111 -* Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept. 112 -* Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring. 113 -* Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards. 114 -* Record approved deviations or options in the machine technical file and update the applicable KB article when the as-built configuration changes. 115 - 116 116