1 1  **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
2 2  
3 -{{toc/}}
4 -
5 5  (% class="box warningmessage" %)
6 6  (((
7 7  **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.
8 -)))
9 9  
10 10  ----
11 11  
12 -= System Identification =
13 -
14 -(% class="table-condensed table-striped" %)
15 -|**Property**|**Specification**
16 -|System type|Integration laser
17 -|Laser classification|Laser Class 4
18 -|Protection rating|IP21
19 -|Available variants|F20, F30, F50, M20, and M30
20 -|Cooling|Low-noise forced air
21 -|Sound level|< 70 dB
22 -
23 -
24 -
25 -= Principal Dimensions =
26 -
27 -[[**Auto-Light principal dimensions and standard optical arrangement. Verify mounting and connector details against the delivered drawings.**>>image:1788844179033-844.png]]
28 -
29 -
30 -= Laser-Source Variants =
31 -
32 -(% class="table-condensed table-striped" %)
33 -|**Model**|**Laser source**|**Nominal power**|**Pulse energy**|**Beam quality**
34 -|F20|Pulsed fiber|20 W|1 mJ|M2 < 1.5
35 -|F30|Pulsed fiber|30 W|1 mJ|M2 < 1.5
36 -|F50|Pulsed fiber|50 W|1 mJ|M2 < 1.8
37 -|M20|Pulsed MOPA fiber|20 W|0.7 mJ|M2 < 1.3
38 -|M30|Pulsed MOPA fiber|30 W|1 mJ|M2 < 1.3
39 -
40 -
41 -
42 -= Pulse and Electrical Data =
43 -
44 -(% class="table-condensed table-striped" %)
45 -|**Model**|**Wavelength**|**Pulse frequency**|**Pulse duration**|**Power consumption**
46 -|F20|1060-1070 nm|20-60 kHz|100 ns|< 200 W
47 -|F30|1060-1070 nm|30-60 kHz|100 ns|< 300 W
48 -|F50|1060-1070 nm|50-100 kHz|100 ns|< 340 W
49 -|M20|1060-1070 nm|2-550 kHz|2-550 ns|< 150 W
50 -|M30|1060-1070 nm|2-550 kHz|2-550 ns|< 170 W
51 -
52 -(% class="box infomessage" %)
53 -(((
54 - **Do not substitute process settings: **These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration.
55 -)))
56 -
57 -
58 -
59 -= Common Optical and Mechanical Data =
60 -
61 -(% class="table-condensed table-striped" %)
62 -|**Property**|**Unit**|**F20 / F30 / F50 / M20 / M30**
63 -|Fibre length|m|3
64 -|Standard lens|-|F-Theta, 160 mm focal length
65 -|Standard working distance|mm|176
66 -|Standard field size|mm|110 x 110
67 -|Lens wavelength|nm|1064
68 -|Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162
69 -|Laser-head dimensions|mm|367 x 131 x 131
70 -
71 -(% class="box warningmessage" %)
72 -(((
73 - **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
74 -)))
75 -
76 -
77 -
78 -= Operating and Installation Conditions =
79 -
80 -(% class="table-condensed table-striped" %)
81 -|**Condition**|**Requirement**
82 -|Ambient temperature|+15 degrees C to +35 degrees C
83 -|Relative humidity|No higher than 90%, non-condensing
84 -|After a major temperature change|Allow the system to return to room temperature before commissioning
85 -|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
86 -|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 -|Process emissions|Provide extraction suitable for the material, fumes, vapors, dust, and particles produced
88 -
89 -
90 -
91 -= Interfaces and Supply - Overview =
92 -
93 -(% class="table-condensed table-striped" %)
94 -|**Connection**|**Description**|**Purpose**
95 -|X0|230 V / 600 W, including main switch|Mains-supply interface
96 -|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
97 -|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND
98 -|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
99 -|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration
100 -
101 -(% class="box errormessage" %)
102 -(((
103 - **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel.
104 -)))
105 -
106 -
107 -
108 -= Verification Before Use =
109 -
110 -* Match the model designation and serial number to the nameplate and order documentation.
111 -* Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept.
112 -* Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring.
113 -* Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards.