Änderungen von Dokument Auto-Light Technical Specifications

Zuletzt geändert von jadomatis am 2026/09/08 07:54

Von Version 2.5
bearbeitet von jadomatis
am 2026/09/08 07:52
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 3.1
bearbeitet von jadomatis
am 2026/09/08 07:54
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -1,5 +1,7 @@
1 1  **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
2 2  
3 +{{toc/}}
4 +
3 3  (% class="box warningmessage" %)
4 4  (((
5 5  **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.
... ... @@ -10,7 +10,7 @@
10 10  = System Identification =
11 11  
12 12  (% class="table-condensed table-striped" %)
13 -|**Property**|**Manual specification**
15 +|**Property**|**Specification**
14 14  |System type|Integration laser
15 15  |Laser classification|Laser Class 4
16 16  |Protection rating|IP21
... ... @@ -27,8 +27,6 @@
27 27  
28 28  = Laser-Source Variants =
29 29  
30 -The F models use a pulsed fiber laser. The M models use a pulsed MOPA fiber laser. Values in both tables are reproduced from the manual's data sheet.
31 -
32 32  (% class="table-condensed table-striped" %)
33 33  |**Model**|**Laser source**|**Nominal power**|**Pulse energy**|**Beam quality**
34 34  |F20|Pulsed fiber|20 W|1 mJ|M2 < 1.5
... ... @@ -84,7 +84,7 @@
84 84  |After a major temperature change|Allow the system to return to room temperature before commissioning
85 85  |Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
86 86  |Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 -|Process emissions|Provide extraction suitable for the material, fumes, vapours, dust, and particles produced
87 +|Process emissions|Provide extraction suitable for the material, fumes, vapors, dust, and particles produced
88 88  
89 89  
90 90  
... ... @@ -91,7 +91,7 @@
91 91  = Interfaces and Supply - Overview =
92 92  
93 93  (% class="table-condensed table-striped" %)
94 -|**Connection**|**Manual description**|**Purpose**
94 +|**Connection**|**Description**|**Purpose**
95 95  |X0|230 V / 600 W, including main switch|Mains-supply interface
96 96  |X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
97 97  |X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND
... ... @@ -100,5 +100,17 @@
100 100  
101 101  (% class="box errormessage" %)
102 102  (((
103 -
103 + **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel.
104 104  )))
105 +
106 +
107 +
108 += Verification Before Use =
109 +
110 +* Match the model designation and serial number to the nameplate and order documentation.
111 +* Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept.
112 +* Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring.
113 +* Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards.
114 +* Record approved deviations or options in the machine technical file and update the applicable KB article when the as-built configuration changes.
115 +