1 1  **Description**: Learn to identify the standard Auto-Light mechanical, optical, laser-source, electrical, and environmental data. Auto-Light is a modular Class 4 integration laser available in F20, F30, F50, M20, and M30 variants.
2 2  
3 +{{toc/}}
4 +
3 3  (% class="box warningmessage" %)
4 4  (((
5 5  **Configuration control: **The values below describe the standard configurations. The nameplate, order confirmation, delivered drawings, and approved electrical documentation for the specific system take precedence. Options, replacement components, or a different lens can change relevant values.
... ... @@ -10,7 +10,7 @@
10 10  = System Identification =
11 11  
12 12  (% class="table-condensed table-striped" %)
13 -|**Property**|**Manual specification**
15 +|**Property**|**Specification**
14 14  |System type|Integration laser
15 15  |Laser classification|Laser Class 4
16 16  |Protection rating|IP21
... ... @@ -18,4 +18,97 @@
18 18  |Cooling|Low-noise forced air
19 19  |Sound level|< 70 dB
20 20  
21 - /h1
23 +
24 +
25 += Principal Dimensions =
26 +
27 +[[**Auto-Light principal dimensions and standard optical arrangement. Verify mounting and connector details against the delivered drawings.**>>image:1788844179033-844.png]]
28 +
29 +
30 += Laser-Source Variants =
31 +
32 +(% class="table-condensed table-striped" %)
33 +|**Model**|**Laser source**|**Nominal power**|**Pulse energy**|**Beam quality**
34 +|F20|Pulsed fiber|20 W|1 mJ|M2 < 1.5
35 +|F30|Pulsed fiber|30 W|1 mJ|M2 < 1.5
36 +|F50|Pulsed fiber|50 W|1 mJ|M2 < 1.8
37 +|M20|Pulsed MOPA fiber|20 W|0.7 mJ|M2 < 1.3
38 +|M30|Pulsed MOPA fiber|30 W|1 mJ|M2 < 1.3
39 +
40 +
41 +
42 += Pulse and Electrical Data =
43 +
44 +(% class="table-condensed table-striped" %)
45 +|**Model**|**Wavelength**|**Pulse frequency**|**Pulse duration**|**Power consumption**
46 +|F20|1060-1070 nm|20-60 kHz|100 ns|< 200 W
47 +|F30|1060-1070 nm|30-60 kHz|100 ns|< 300 W
48 +|F50|1060-1070 nm|50-100 kHz|100 ns|< 340 W
49 +|M20|1060-1070 nm|2-550 kHz|2-550 ns|< 150 W
50 +|M30|1060-1070 nm|2-550 kHz|2-550 ns|< 170 W
51 +
52 +(% class="box infomessage" %)
53 +(((
54 + **Do not substitute process settings: **These ranges describe the laser-source variants; they are not marking recipes. Production power, speed, frequency, pulse, hatch, and pass settings must come from the released process for the actual material and installed configuration.
55 +)))
56 +
57 +
58 +
59 += Common Optical and Mechanical Data =
60 +
61 +(% class="table-condensed table-striped" %)
62 +|**Property**|**Unit**|**F20 / F30 / F50 / M20 / M30**
63 +|Fibre length|m|3
64 +|Standard lens|-|F-Theta, 160 mm focal length
65 +|Standard working distance|mm|176
66 +|Standard field size|mm|110 x 110
67 +|Lens wavelength|nm|1064
68 +|Laser-rack dimensions (L x W x H)|mm|550 x 441 x 162
69 +|Laser-head dimensions|mm|367 x 131 x 131
70 +
71 +(% class="box warningmessage" %)
72 +(((
73 + **Standard optics: **The 176 mm working distance and 110 x 110 mm field apply to the listed 160 mm F-Theta lens. Confirm the actual lens before setting the fixture height, enclosure geometry, extraction nozzle, or marking boundary.
74 +)))
75 +
76 +
77 +
78 += Operating and Installation Conditions =
79 +
80 +(% class="table-condensed table-striped" %)
81 +|**Condition**|**Requirement**
82 +|Ambient temperature|+15 degrees C to +35 degrees C
83 +|Relative humidity|No higher than 90%, non-condensing
84 +|After a major temperature change|Allow the system to return to room temperature before commissioning
85 +|Cooling-air openings|Keep approximately 15 cm clear and do not obstruct ventilation slots or filter mats
86 +|Operating environment|Avoid mechanical loads, vibration, impact, dust accumulation, and heat build-up
87 +|Process emissions|Provide extraction suitable for the material, fumes, vapors, dust, and particles produced
88 +
89 +
90 +
91 += Interfaces and Supply - Overview =
92 +
93 +(% class="table-condensed table-striped" %)
94 +|**Connection**|**Description**|**Purpose**
95 +|X0|230 V / 600 W, including main switch|Mains-supply interface
96 +|X1|25-pin Sub-D socket|Dual emergency-stop and shutter circuits, acknowledgements, external START/STOP, and 24 V status/production I/O
97 +|X1 outputs|24 V when active; Imax 250 mA|External status and assigned production outputs referenced to X1.25 GND
98 +|X2|25-pin Sub-D plug|Direction, step, and zero signals for X, Y, Z, and R axes, with documented +5 V and GND
99 +|Rack data connections|USB, Ethernet, and HDMI|Workstation, network, and display connections according to the delivered integration
100 +
101 +(% class="box errormessage" %)
102 +(((
103 + **Safety interface: **X1 is part of the integrated safety and control boundary. A connector rating or pin description is not a complete safety design. Do not bridge, modify, or test safety circuits unless the system is isolated and the work is performed under the approved procedure by authorised integration personnel.
104 +)))
105 +
106 +
107 +
108 += Verification Before Use =
109 +
110 +* Match the model designation and serial number to the nameplate and order documentation.
111 +* Confirm the installed lens, focal length, working distance, marking field, and wavelength before fixing the mechanical design or laser-protection concept.
112 +* Verify X0 supply data and all X1/X2 assignments against the delivered electrical drawings; do not rely on this summary for wiring.
113 +* Confirm that the host machine provides and validates the required enclosure, access monitoring, emergency stop, shutter control, emission warning, extraction, and other site-specific safeguards.
114 +* Record approved deviations or options in the machine technical file and update the applicable KB article when the as-built configuration changes.
115 +
116 +