Auto-Light Interfaces and Connection Examples

Version 20.9 by jadomatis on 2026/09/08 08:55

Description: Learn how to identify the Auto-Light X0 mains connection, X1 safety and production interface, and X2 axis interface. The pin assignments and diagrams are reproduced from the supplied operating manual in English.

Qualified integration work only: The manual diagrams are connection examples, not a complete safety design or permission to wire an energised system. An appropriately qualified integrator must design, calculate, isolate, wire, validate, and document the complete safety-related control system for the delivered machine.


Connection Locations

X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.

1788848686104-199.png

Auto-Light front and rear rack panels. X1 and X2 are located on the rear panel.

X0 Mains Supply

X0 is a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.

Keep X0 separate from model consumption data: The X0 declaration is the documented supply-interface value. The lower power-consumption figures listed for individual laser-source variants in Technical Specifications do not replace the delivered supply and protection requirements.

X1 Laser Interface - Pin Assignment

Pin(s)SignalManual description / use
1-2Emergency-stop circuit 1External wiring through a safety module required
3-4Emergency-stop circuit 2External wiring through a safety module required
5-6Emergency-stop acknowledgementAcknowledgement contact
7-8Shutter circuit 1External wiring through a safety module required
9-10Shutter circuit 2External wiring through a safety module required
11-12Shutter acknowledgementAcknowledgement contact
13+24 VSupply voltage for inputs
14External START24 V input
15External STOP24 V input
16Emergency-stop status24 V output
17SHUTTER status24 V output
18LASER READY status24 V output
19LASER BUSY status24 V output
20LASER END status24 V output
21-22Inputs 4 and 524 V inputs
23-24Outputs 4 and 524 V outputs
25GNDGround for outputs

X1 Emergency-Stop Connection Examples

Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine.

1788848686108-737.png

Example: dual emergency-stop circuits at X1.1-X1.4.

Emergency-stop acknowledgement is provided at X1.5/X1.6. The source manual states that acknowledgement is required at every restart of the system and after every operation of the emergency stop.

1788848686109-592.png

Example: emergency-stop acknowledgement at X1.5/X1.6.

Reset is not a safety function: Acknowledgement may be accepted only after the cause of the stop has been removed, the hazard area is clear, and the host safety system permits reset. It must not initiate hazardous movement or laser emission by itself.

X1 Shutter Connection Examples

The shutter interface also uses two external channels. Circuit 1 uses X1.7/X1.8 and circuit 2 uses X1.9/X1.10. The manual requires the shutter circuit to be interrupted whenever the protective enclosure is opened.

1788848686109-891.png

Example: dual shutter circuits at X1.7-X1.10.

Shutter acknowledgement is provided at X1.11/X1.12. A closed and validated shutter circuit enables the laser system's active mode. The source states that laser-energy emission is possible only in active mode; a closed circuit is permission, not a marking command.

1788848686110-868.png

Example: shutter acknowledgement at X1.11/X1.12.

Integration requirement: The protective enclosure, access monitoring, shutter channels, acknowledgement logic, emergency stop, and emission warning must operate as one validated safety concept. Never use the X1 examples as a stand-alone circuit design.

X1 External Inputs

The manual states that the X1 inputs are switched using the internal 24 V auxiliary supply at X1.13. Its example closes an external contact between X1.13 and X1.14 to issue External START. X1.15 is External STOP; X1.21 and X1.22 are Inputs 4 and 5.

1788848686111-492.png

Example: external input switched from X1.13 to X1.14.

X1 External Outputs

The source states that an active output supplies 24 V and is used with output ground at X1.25. The maximum output current is 250 mA. Status outputs are X1.16-X1.20; assignable Outputs 4 and 5 are X1.23/X1.24.

1788848686112-729.png

External-output example. Confirm the selected output and load connection against the delivered electrical drawing.

Diagram limitation: The source output figure labels X1.13, X1.14, X1.23, X1.24, and X1.25 but does not show a complete external-load connection for every output. Do not infer missing wiring from the illustration. Verify polarity, output selection, load type, current, suppression, and common reference before connection.

X2 Axes Interface - 25-pin Sub-D Plug

X2 provides direction and step outputs for X, Y, Z, and R axes, zero signals, GND, and a documented +5 V supply. The image below reproduces the complete English pin table from the manual translation.

PinDirectionDescription
1OutputDirection X
2OutputStep X
3OutputDirection Y
4OutputStep Y
5OutputDirection Z
6OutputStep Z
7OutputDirection R
8OutputStep R
9OutputZero X
10-Not connected
11InputZero Y
12-Not connected
13InputZero Z
14-Not connected
15InputZero R
16-Not connected
17OutputGND
18-Not connected
19Output+5V supply
20-Not connected
21-Not connected
22-Not connected
23-Not connected
24-Not connected
25-Not connected

X2 Functional Grouping

Axis / functionPin(s)Direction stated in manual
X axis1 Direction; 2 Step; 9 ZeroOutputs on all three pins, as stated
Y axis3 Direction; 4 Step; 11 ZeroDirection/Step outputs; Zero input
Z axis5 Direction; 6 Step; 13 ZeroDirection/Step outputs; Zero input
R axis7 Direction; 8 Step; 15 ZeroDirection/Step outputs; Zero input
Reference17 GND; 19 +5 VOutputs, as stated
Not connected10, 12, 14, 16, 18, 20-25NC

Integration and Commissioning Checks

  • Confirm X1 is a 25-pin Sub-D socket and X2 is a 25-pin Sub-D plug before preparing mating connectors.

  • Keep safety functions, production commands, status monitoring, axis signals, and workstation connections identified separately in the electrical documentation.
  • Verify conductor identification, shielding, routing, protective bonding, connector retention, strain relief, and separation from interference sources for the delivered installation.
  • Validate both emergency-stop channels, both shutter channels, acknowledgement behaviour, guard opening, status outputs, and prevention of unexpected restart before laser operation is released.
  • Confirm the External START/STOP logic and LASER READY/BUSY/END sequence against the host control specification without bypassing any safety permission.
  • For every installed axis, verify direction, step scaling, travel limits, zero/reference behaviour, and safe motion before placing a workpiece in the marking area.
  • Document measured results and obtain the required approval for the complete integrated machine, not only the Auto-Light rack.