1 -**Description**: Learn how to identify the Auto-Light X0 mains connection, X1 safety and production interface, and X2 axis interface. The pin assignments and diagrams are reproduced from the supplied operating manual in English.
2 -
3 -(% class="box errormessage" %)
4 -(((
5 -**Qualified integration work only: **The manual diagrams are connection examples, not a complete safety design or permission to wire an energised system. An appropriately qualified integrator must design, calculate, isolate, wire, validate, and document the complete safety-related control system for the delivered machine.
6 -)))
7 -
8 -----
9 -
10 -= Connection Locations =
11 -
12 -X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
13 -
14 -[[image:1788847354911-289.png]]
15 -
16 -
17 -= X0 Mains Supply =
18 -
19 -The manual identifies X0 as a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
20 -
21 -(% class="box warningmessage" %)
22 -(((
23 -**Keep X0 separate from model consumption data: **The X0 declaration is the documented supply-interface value. The lower power-consumption figures listed for individual laser-source variants in Technical Specifications do not replace the delivered supply and protection requirements.
24 -)))
25 -
26 -
27 -= X1 Laser Interface - Pin Assignment =
28 -
29 -(% class="table-condensed table-striped" %)
30 -|**Pin(s)**|**Signal**|**Manual description / use**
31 -|1-2|Emergency-stop circuit 1|External wiring through a safety module required
32 -|3-4|Emergency-stop circuit 2|External wiring through a safety module required
33 -|5-6|Emergency-stop acknowledgement|Acknowledgement contact
34 -|7-8|Shutter circuit 1|External wiring through a safety module required
35 -|9-10|Shutter circuit 2|External wiring through a safety module required
36 -|11-12|Shutter acknowledgement|Acknowledgement contact
37 -|13|+24 V|Supply voltage for inputs
38 -|14|External START|24 V input
39 -|15|External STOP|24 V input
40 -|16|Emergency-stop status|24 V output
41 -|17|SHUTTER status|24 V output
42 -|18|LASER READY status|24 V output
43 -|19|LASER BUSY status|24 V output
44 -|20|LASER END status|24 V output
45 -|21-22|Inputs 4 and 5|24 V inputs
46 -|23-24|Outputs 4 and 5|24 V outputs
47 -|25|GND|Ground for outputs
48 -
49 -
50 -
51 -= X1 Emergency-Stop Connection Examples =
52 -
53 -The manual example routes two external emergency-stop channels through a safety module. Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine.
54 -
55 -[[**Example: dual emergency-stop circuits at X1.1-X1.4.**>>image:1788848413333-368.png]]
56 -
57 -
58 -Emergency-stop acknowledgement is provided at X1.5/X1.6. TAcknowledgement is required at every restart of the system and after every operation of the emergency stop.
59 -
60 -[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788848413336-918.png]]
61 -
62 -
1788847354911-289.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -278.1 KB
Content
1788848413333-368.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -39.1 KB
Content
1788848413336-918.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -14.1 KB
Content