Details

Seiteneigenschaften
Inhalt
... ... @@ -7,15 +7,56 @@
7 7  
8 8  ----
9 9  
10 -
11 11  = Connection Locations =
12 12  
13 13  X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
14 14  
15 -= Connection Locations =
14 +[[image:1788847354911-289.png]]
15 +
16 16  
17 -X0 mains power, X1 safety and production I/O, and X2 axis control are located at the rear of the laser rack. USB, Ethernet, and HDMI connections support the delivered workstation, network, and display arrangement.
17 += X0 Mains Supply =
18 18  
19 -[[image:image-20260908090217-2.png]]
19 +The manual identifies X0 as a 230 V / 600 W mains-supply interface including the main switch. Before connection, verify the actual nameplate, protective conductor, supply frequency, protective measures, disconnecting means, cable, plug, and site electrical documentation.
20 20  
21 +(% class="box warningmessage" %)
22 +(((
23 +**Keep X0 separate from model consumption data: **The X0 declaration is the documented supply-interface value. The lower power-consumption figures listed for individual laser-source variants in Technical Specifications do not replace the delivered supply and protection requirements.
24 +)))
25 +
26 +
27 += X1 Laser Interface - Pin Assignment =
28 +
29 +(% class="table-condensed table-striped" %)
30 +|**Pin(s)**|**Signal**|**Manual description / use**
31 +|1-2|Emergency-stop circuit 1|External wiring through a safety module required
32 +|3-4|Emergency-stop circuit 2|External wiring through a safety module required
33 +|5-6|Emergency-stop acknowledgement|Acknowledgement contact
34 +|7-8|Shutter circuit 1|External wiring through a safety module required
35 +|9-10|Shutter circuit 2|External wiring through a safety module required
36 +|11-12|Shutter acknowledgement|Acknowledgement contact
37 +|13|+24 V|Supply voltage for inputs
38 +|14|External START|24 V input
39 +|15|External STOP|24 V input
40 +|16|Emergency-stop status|24 V output
41 +|17|SHUTTER status|24 V output
42 +|18|LASER READY status|24 V output
43 +|19|LASER BUSY status|24 V output
44 +|20|LASER END status|24 V output
45 +|21-22|Inputs 4 and 5|24 V inputs
46 +|23-24|Outputs 4 and 5|24 V outputs
47 +|25|GND|Ground for outputs
48 +
49 +
50 +
51 += X1 Emergency-Stop Connection Examples =
52 +
53 +The manual example routes two external emergency-stop channels through a safety module. Circuit 1 uses X1.1/X1.2 and circuit 2 uses X1.3/X1.4. Both channels belong to the integrated safety system and must be assessed and validated as part of the host machine.
54 +
55 +[[**Example: dual emergency-stop circuits at X1.1-X1.4.**>>image:1788848413333-368.png]]
56 +
57 +
58 +Emergency-stop acknowledgement is provided at X1.5/X1.6. TAcknowledgement is required at every restart of the system and after every operation of the emergency stop.
59 +
60 +[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788848413336-918.png]]
61 +
21 21  
1788847354911-289.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +278.1 KB
Inhalt
1788848413333-368.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +39.1 KB
Inhalt
1788848413336-918.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +14.1 KB
Inhalt