Learn about the typical wear parts and consumables for Multi-Light workstation and how to replace them. Always use original parts and follow the maintenance instructions in the manual.
Filter Mat
What it does: Protects the electronics from dust; keeps cooling airflow stable.
Location: Behind the front ventilation slots of the laser plug-in unit or the PC.
When to replace: Inspect regularly; replace when soiled to maintain proper cooling.
Extraction System Filters
What do they do: Remove fumes, vapors, aerosols, and dusts generated during marking; protect personnel and optics.
When to replace: At least annually check the main filter; replace if contaminated. Frequency depends on workload/material.
Tip: Using an extraction unit is highly recommended for plastics and larger material removal (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted.
Laser Protection Window
What it does: Provides certified protection at the laser wavelength and allows visual monitoring.
When to replace: If scratched, cracked, or clouded - stop operation and replace before further use. Clean only with approved methods.
Perimeter Seals/Cladding Fasteners
What they do: Ensure the protective cabin remains Class 1 tight (no radiation leakage).
When to replace: If missing, damaged, or loose. Operation with compromised seals/cladding is not permitted.
Optics Care Material
What to stock:
- Approved lens cleaning wipes/lint-free tissues
- High-purity alcohol (>98%) for optics cleaning
- Small hand air bulb (no compressed air)
When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique.
Lenses/Objectives
What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field)
When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change.
Service Items (performed by Schilling/authorized personnel)
Typical items listed in the service scope include:
- Cleaning of fans, replacement of filter mats (key for lifetime/performance)
- Cleaning of laser source and optics, laser power measurement (with protocol)
- Check and correction of working field and pilot laser alignment.
- Functional checks of software and laser files, measurement of electrical connection (per VDE 0701-0702), and refresher training if needed.
Replacement Laser