Changes for page Spare Parts and Consumables
Last modified by jadomatis on 2025/10/06 07:31
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Laser Marking Machines. Schilling Marking Systems Multi-Light.Overview.WebHome1 +Laser Marking Machines.Overview.WebHome - Content
-
... ... @@ -1,62 +1,64 @@ 1 1 Learn about the typical wear parts and consumables for Multi-Light workstation and how to replace them. Always use original parts and follow the maintenance instructions in the manual. 2 2 3 - 4 4 = Filter Mat = 5 5 6 -What it does: Protects the electronics from dust; keeps cooling airflow stable. 7 -Location: Behind the front ventilation slots of the laser plug-in unit or the PC. 8 -When to replace: Inspect regularly; replace when soiled to maintain proper cooling. 5 +**What it does**: Protects the electronics from dust; keeps cooling airflow stable. 6 +**Location**: Behind the **front ventilation** slots of the laser plug-in unit or the PC. 7 +**When to replace**: Inspect regularly; **replace when soiled **to maintain proper cooling. 9 9 10 10 11 11 = Extraction System Filters = 12 12 13 -What do they do: Remove fumes, vapors, aerosols, and dusts generated during marking; protect personnel and optics. 14 -When to replace: At least annually check the main filter; replace if contaminated. Frequency depends on workload/material. 15 -Tip: Using an extraction unit is highly recommended for plastics and larger material removal (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted. 12 +**What do they do**: Remove **fumes**, **vapors**, **aerosols**, **and dusts** generated during marking; protect personnel and optics. 13 +**When to replace**: At least **annually check the main filter**; **replace if contaminated**. Frequency depends on workload/material. 14 +**Tip**: Using an extraction unit is highly recommended for **plastics **and **larger material removal** (e.g., anodized/painted/coated parts). Systems are available in multiple sizes and can be retrofitted. 16 16 17 17 18 18 = Laser Protection Window = 19 19 20 -What it does: Provides certified protection at the laser wavelength and allows visual monitoring. 21 -When to replace: If scratched, cracked, or clouded - stop operation and replace before further use. Clean only with approved methods. 19 +**What it does**: Provides certified protection at the laser wavelength and allows visual monitoring. 20 +**When to replace**: If **scratched**, **cracked**, or **clouded **- stop operation and replace before further use. Clean only with approved methods. 22 22 23 23 24 24 = Perimeter Seals/Cladding Fasteners = 25 25 26 -What they do: Ensure the protective cabin remains Class 1 tight (no radiation leakage). 27 -When to replace: If missing, damaged, or loose. Operation with compromised seals/cladding is not permitted. 25 +**What they do**: Ensure the protective cabin remains **Class 1** tight (no radiation leakage). 26 +**When to replace**: If **missing**, **damaged**, or **loose**. Operation with compromised seals/cladding is **not permitted**. 28 28 29 29 30 30 = Optics Care Material = 31 31 32 -What to stock: 31 +**What to stock**: 33 33 34 -* Approved lens cleaning wipes/lint-free tissues 35 -* High-purity alcohol (>98%) for optics cleaning 36 -* Small hand air bulb (no compressed air) 37 -When to use: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique. 33 +* Approved **lens cleaning wipes**/lint-free tissues 34 +* **High-purity alcohol** (>98%) for optics cleaning 35 +* Small **hand air bulb** (no compressed air) 36 +**When to use**: As needed when contamination is evident; follow gentle, center-to-edge cleaning technique. 38 38 39 39 40 40 41 41 = Lenses/Objectives = 42 42 43 -What they do: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field) 44 -When to replace/add: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change. 42 +**What they do**: Change field/spot size (e.g., F-Theta f=160 mm for 110 x 110 mm field) 43 +**When to replace/add**: When application requires a different field or when an optic is irreparably damaged (scratched). Re-focus after any lens change. 45 45 46 46 47 47 = Service Items (performed by Schilling/authorized personnel) = 48 48 49 -Typical items listed in the service scope include: 48 +Typical items listed in the **service scope** include: 50 50 51 -* Cleaning of fans, replacement of filter mats (key for lifetime/performance) 52 -* Cleaning of laser source and optics, laser power measurement (with protocol) 53 -* Check and correction of working field and pilot laser alignment. 54 -* Functional checks of software and laser files, measurement of electrical connection (per VDE 0701-0702), and refresher training if needed. 50 +* **Cleaning **of fans, **replacement of filter mats** (key for lifetime/performance) 51 +* Cleaning of laser source and optics, **laser power measurement** (with protocol) 52 +* Check and correction of **working field** and **pilot laser **alignment. 53 +* Functional checks of **software** and **laser files**, measurement of **electrical connection** (per VDE 0701-0702), and refresher training if needed. 55 55 56 56 57 57 58 -= Replacement Laser = 57 += Replacement Laser (during repair) = 59 59 59 +Schilling can provide a **replacement laser** for the repair period to keep you productive; contact service to arrange. 60 60 61 61 62 - 62 += Ordering and Support = 63 + 64 +For spare parts, filters, or service contact **Schilling Marking Systems GmbH **- Service : **+49 (7461) 9472-16** or [[service@schilling-marking.de>>mailto:service@schilling-marking.de]]. Have your **serial number** and** software version** ready.