Wiki source code of Commissioning and First Start-Up
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | = Preconditions (Before Switching On) = | ||
| 2 | |||
| 3 | Confirm the following before applying power: | ||
| 4 | |||
| 5 | * Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF. | ||
| 6 | * Protective housing and door interlocks are intact; laser viewing window shows now damage. | ||
| 7 | * Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands. | ||
| 8 | * Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport. | ||
| 9 | * Airflow at 19" drawers is unobstructed; filter mats are clean to prevent heat build-up. | ||
| 10 | * Operator is familiar with laser safety requirements; responsibilities are defined. | ||
| 11 | Note: The Multi-Light containe |