Version 1.5 by jadomatis on 2025/09/29 11:19

Show last authors
1 = Preconditions (Before Switching On) =
2
3 Confirm the following before applying power:
4
5 * Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF.
6 * Protective housing and door interlocks are intact; laser viewing window shows now damage.
7 * Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands.
8 * Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport.
9 * Airflow at 19" drawers is unobstructed;