Version 1.10 by jadomatis on 2025/09/29 12:09

Show last authors
1 = Preconditions (Before Switching On) =
2
3 Confirm the following before applying power:
4
5 * Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF.
6 * Protective housing and door interlocks are intact; laser viewing window shows now damage.
7 * Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands.
8 * Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport.
9 * Airflow at 19" drawers is unobstructed; filter mats are clean to prevent heat build-up.
10 * Operator is familiar with laser safety requirements; responsibilities are defined.
11 Note: The Multi-Light contains a Class 4 source operated as Class 1 in the closed cabin. Never bypass safety devices.
12
13
14
15 = Electrical Start-Up =
16
17 1. Connect the system to the specified mains supply. Ensure extraction is running.
18 1. Set the mains switch to ON. Internal electronics initialize; status indicators light as described on the operator panel.
19 1. Power on the control PC (or workstation) and peripherals needed for operation.
20