Changes for page Commissioning and First Start-Up
Last modified by jadomatis on 2025/10/08 11:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -49,7 +49,7 @@ 49 49 = Z-Axis Focusing = 50 50 51 51 1. Place the workpiece/fixture in the work chamber and close the **manual lift door**. 52 -1. Use the Z-axis adjustment to setthefocuspointaccordingto theheight of the markingsurface.Upon delivery,thezero point is calibratedto the heightof the baseplate.The Z-axis moves to thecorrect point according totheparametersofthe workpiece.Check thefocus pointandadjust if necessary.52 +1. Use the **automatic Z-axis** to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height. 53 53 1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual. 54 54 55 55