Changes for page Commissioning and First Start-Up
Last modified by jadomatis on 2025/10/08 11:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -49,7 +49,7 @@ 49 49 = Z-Axis Focusing = 50 50 51 51 1. Place the workpiece/fixture in the work chamber and close the **manual lift door**. 52 -1. Use the Z-axis adjustment to setthefocuspointaccordingto theheight of the markingsurface.Upon delivery,thezero point is calibratedto the heightof the baseplate.The Z-axis moves to thecorrect point according totheparametersofthe workpiece.Check thefocus pointandadjust if necessary.52 +1. Use the **automatic Z-axis** to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height. 53 53 1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual. 54 54 55 55 ... ... @@ -64,7 +64,7 @@ 64 64 = First Test Mark = 65 65 66 66 1. With the cabin closed and interlocks engaged, execute a **short test mark** on a sample of the target material. 67 -1. Observe quality and adjust **parameters **(e.g., reduce power/increase speed) as needed. Multiple **repetitions **may be used for depth, but monitor temperature with a suitable temperature reading device to reduce fire risk.67 +1. Observe quality and adjust **parameters **(e.g., reduce power/increase speed) as needed. Multiple **repetitions **may be used for depth, but monitor temperature to reduce fire risk. 68 68 1. If unexpected behavior occurs, press **STOP**/**EMERGENCY-STOP**, investigate messages in **Notifications**, and correct the cause before resuming. 69 69 70 70