... ... @@ -49,7 +49,7 @@
49 49  = Z-Axis Focusing =
50 50  
51 51  1. Place the workpiece/fixture in the work chamber and close the **manual lift door**.
52 -1. Use the Z-axis adjustment to set the focus point according to the height of the marking surface. Upon delivery, the zero point is calibrated to the height of the base plate. The Z-axis moves to the correct point according to the parameters of the workpiece. Check the focus point and adjust if necessary.
52 +1. Use the **automatic Z-axis** to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height.
53 53  1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual.
54 54  
55 55  
... ... @@ -64,7 +64,7 @@
64 64  = First Test Mark =
65 65  
66 66  1. With the cabin closed and interlocks engaged, execute a **short test mark** on a sample of the target material.
67 -1. Observe quality and adjust **parameters **(e.g., reduce power/increase speed) as needed. Multiple **repetitions **may be used for depth, but monitor temperature with a suitable temperature reading device to reduce fire risk.
67 +1. Observe quality and adjust **parameters **(e.g., reduce power/increase speed) as needed. Multiple **repetitions **may be used for depth, but monitor temperature to reduce fire risk.
68 68  1. If unexpected behavior occurs, press **STOP**/**EMERGENCY-STOP**, investigate messages in **Notifications**, and correct the cause before resuming.
69 69  