Changes for page Commissioning and First Start-Up
Last modified by jadomatis on 2025/10/08 11:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -49,7 +49,7 @@ 49 49 = Z-Axis Focusing = 50 50 51 51 1. Place the workpiece/fixture in the work chamber and close the **manual lift door**. 52 -1. Use the **automaticZ-axis**to set focus to the surface(perlensfocaldistance).Followtheon-screen/readoutguidance forfocalheight.52 +1. Use the Z-axis adjustment to set the focus point according to the height of the marking surface. Upon delivery, the zero point is calibrated to the height of the base plate. The Z-axis moves to the correct point according to the parameters of the workpiece. Check the focus point and adjust if necessary. 53 53 1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual. 54 54 55 55