Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Laser Marking Machines.Schilling Marking Systems Multi-Light.Getting Started.WebHome
1 +Laser Marking Machines.Getting Started.WebHome
Content
... ... @@ -1,5 +1,10 @@
1 -This procedure describes how to bring the Multi-Light workstation into operation safely after transport or installation. **Only qualified personnel **may commission the system. Observer all safety notes before switching on.
1 +This procedure describes how to bring the Multi-Light or Multi-Light PLUS workstations into operation safely after transport or installation.
2 2  
3 +(% class="box warningmessage" %)
4 +(((
5 +**Only qualified personnel may commission the system. Observe all safety notes before switching on.**
6 +)))
7 +
3 3  = Preconditions (Before Switching On) =
4 4  
5 5  Confirm the following before applying power:
... ... @@ -11,7 +11,7 @@
11 11  * **Airflow **at 19" drawers is unobstructed; **filter mats** are clean to prevent heat build-up.
12 12  * **Fume extraction **is installed and operational (mandatory for personnel safety and to protect optics).
13 13  * Operator is familiar with **laser safety** requirements; responsibilities are defined.
14 -**Note**: The Multi-Light contains a **Class 4 **source operated as **Class 1** in the closed cabin. Never bypass safety devices.
19 +**Note**: The Multi-Light and Multi-Light PLUS both contain a **Class 4 **laser** **source operated as **Class 1** in the closed cabin. Never bypass safety devices.
15 15  
16 16  
17 17  
... ... @@ -44,7 +44,7 @@
44 44  = Z-Axis Focusing =
45 45  
46 46  1. Place the workpiece/fixture in the work chamber and close the **manual lift door**.
47 -1. Use the **automatic Z-axis** to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height.
52 +1. Use the Z-axis adjustment to set the focus point according to the height of the marking surface. Upon delivery, the zero point is calibrated to the height of the base plate. The Z-axis moves to the correct point according to the parameters of the workpiece. Check the focus point and adjust if necessary.
48 48  1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual.
49 49  
50 50  
... ... @@ -59,7 +59,7 @@
59 59  = First Test Mark =
60 60  
61 61  1. With the cabin closed and interlocks engaged, execute a **short test mark** on a sample of the target material.
62 -1. Observe quality and adjust **parameters **(e.g., reduce power/increase speed) as needed. Multiple **repetitions **may be used for depth, but monitor temperature to reduce fire risk.
67 +1. Observe quality and adjust **parameters **(e.g., reduce power/increase speed) as needed. Multiple **repetitions **may be used for depth, but monitor temperature with a suitable temperature reading device to reduce fire risk.
63 63  1. If unexpected behavior occurs, press **STOP**/**EMERGENCY-STOP**, investigate messages in **Notifications**, and correct the cause before resuming.
64 64  
65 65