1 +This procedure describes how to bring the Multi-Light or Multi-Light PLUS workstations into operation safely after transport or installation.
2 +
3 +(% class="box warningmessage" %)
4 +(((
5 +**Only qualified personnel may commission the system. Observe all safety notes before switching on.**
6 +)))
7 +
1 1  = Preconditions (Before Switching On) =
2 2  
3 3  Confirm the following before applying power:
4 4  
5 -* Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF.
6 -* Protective housing and door interlocks are intact; laser viewing window shows now damage.
7 -* Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands.
8 -* Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport.
9 -* Airflow at 19" drawers is unobstructed; filter mats are clean to prevent heat build-up.
10 -* Operator is familiar with laser safety requirements; responsibilities are defined.
11 -Note: The Multi-Light contains a Class 4 source operated as Class 1 in the closed cabin. Never bypass safety devices.
12 +* **Electrical installation is correct**; mains **voltage and frequency **match the rating place. Main switch is OFF.
13 +* **Protective housing** and **door interlocks** are intact; **laser viewing window** shows now damage.
14 +* **Optics are clean**; remove any **transport/lens cover** only now. Avoid touching optics with bare hands.
15 +* **Ambient conditions**: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport.
16 +* **Airflow **at 19" drawers is unobstructed; **filter mats** are clean to prevent heat build-up.
17 +* **Fume extraction **is installed and operational (mandatory for personnel safety and to protect optics).
18 +* Operator is familiar with **laser safety** requirements; responsibilities are defined.
19 +**Note**: The Multi-Light and Multi-Light PLUS both contain a **Class 4 **laser** **source operated as **Class 1** in the closed cabin. Never bypass safety devices.
12 12  
13 13  
14 14  
15 15  = Electrical Start-Up =
16 16  
17 -1. Connect the system to the specified mains supply. Ensure extraction is running.
18 -1. Set the mains switch to ON. Internal electronics initialize; status indicators light as
25 +1. Connect the system to the specified **mains supply**. Ensure extraction is running.
26 +1. Set the **mains switch to ON**. Internal electronics initialize; status indicators light as described on the operator panel.
27 +1. Power on the **control PC** (or workstation) and peripherals needed for operation.
28 +
29 +
30 +
31 += Software and Device Connection =
32 +
33 +1. Launch the **AnyMarker Designer **software.
34 +1. Verify communication with the **laser controller** in the software (device connected, parameters readable).
35 +If connection fails, switch **OFF**, check cabling and restart.
36 +
37 +{{warning}}
38 +**Important: Only start the laser software when the laser is switched on. If the laser is switched on while the software is running, the system will not work.**
39 +{{/warning}}
40 +
41 +
42 += Initial Checks With Pilot Laser =
43 +
44 +* Load or create a **test layout** in AnyMarker Designer.
45 +* Enable the** pilot laser **to project contours on the workpiece; verify **orientation and placement** without laser emission. Keep the door closed.
46 +
47 +
48 +
49 += Z-Axis Focusing =
50 +
51 +1. Place the workpiece/fixture in the work chamber and close the **manual lift door**.
52 +1. Use the Z-axis adjustment to set the focus point according to the height of the marking surface. Upon delivery, the zero point is calibrated to the height of the base plate. The Z-axis moves to the correct point according to the parameters of the workpiece. Check the focus point and adjust if necessary.
53 +1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual.
54 +
55 +
56 +
57 += Parameter Verification =
58 +
59 +* Select a verified **marking parameter set** (power, speed, frequency, fill). Start with conservative energy to avoid burning or glare.
60 +* Ensure extraction is active to remove **gases**, **vapors**, **aerosols**, **and dust** during test marking.
61 +
62 +
63 +
64 += First Test Mark =
65 +
66 +1. With the cabin closed and interlocks engaged, execute a **short test mark** on a sample of the target material.
67 +1. Observe quality and adjust **parameters **(e.g., reduce power/increase speed) as needed. Multiple **repetitions **may be used for depth, but monitor temperature with a suitable temperature reading device to reduce fire risk.
68 +1. If unexpected behavior occurs, press **STOP**/**EMERGENCY-STOP**, investigate messages in **Notifications**, and correct the cause before resuming.
69 +
70 +
71 +
72 += Post-Test Verification =
73 +
74 +* Inspect the mark; check legibility/contrast. Clean light residue if necessary.
75 +* Re-check **filters**/**airflow **after prolonged tests. Excess dust must not accumulate.
76 +* Document the **approved parameter set** for production.
77 +
78 +
79 +
80 += Normal Operation Handover =
81 +
82 +* Train operators on **door interlock**, **pilot laser**, **start**/**stop**, and **notifications **usage.
83 +* Emphasize daily** pre-shift checks **(visible damage, labels present, safety devices functional).
84 +
85 +
86 +
87 += Shutdown (End of Day) =
88 +
89 +1. Stop software and close the project.
90 +1. Turn the system **OFF **via main switch; power down extraction as specified.
91 +1. Clean the work area; never leave the machine **unattended **while powered.
92 +
93 +
94 +
95 +