... ... @@ -15,4 +15,24 @@
15 15  = Electrical Start-Up =
16 16  
17 17  1. Connect the system to the specified mains supply. Ensure extraction is running.
18 -1. Set the mains switch to ON. Internal electronics initialize; status indicators light as
18 +1. Set the mains switch to ON. Internal electronics initialize; status indicators light as described on the operator panel.
19 +1. Power on the control PC (or workstation) and peripherals needed for operation.
20 +
21 +
22 +
23 += Software and Device Connection =
24 +
25 +1. Launch the AnyMarker Designer software.
26 +1. Verify communication with the laser controller in the software (device connected, parameters readable).
27 +If connection fails, switch OFF, check cabling and restart.
28 +
29 +
30 +
31 += Initial Checks With Pilot Laser =
32 +
33 +* Load or create a test layout in AnyMarker Designer.
34 +* Enable the pilot laser to project contours on the workpiece; verify orientation and placement without laser emission. Keep the door closed.