... ... @@ -5,4 +5,27 @@
5 5  * Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF.
6 6  * Protective housing and door interlocks are intact; laser viewing window shows now damage.
7 7  * Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands.
8 -* Ambient conditions: +15C to +35C. R
8 +* Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport.
9 +* Airflow at 19" drawers is unobstructed; filter mats are clean to prevent heat build-up.
10 +* Operator is familiar with laser safety requirements; responsibilities are defined.
11 +Note: The Multi-Light contains a Class 4 source operated as Class 1 in the closed cabin. Never bypass safety devices.
12 +
13 +
14 +
15 += Electrical Start-Up =
16 +
17 +1. Connect the system to the specified mains supply. Ensure extraction is running.
18 +1. Set the mains switch to ON. Internal electronics initialize; status indicators light as described on the operator panel.
19 +1. Power on the control PC (or workstation) and peripherals needed for operation.
20 +
21 +
22 +
23 += Software and Device Connection =
24 +
25 +1. Launch the AnyMarker Designer software.
26 +1. Verify communication with the laser controller in the software (device connected, parameters readable).
27 +If connection fails, switch OFF, check cabling and restart.
28 +
29 +