Last modified by jadomatis on 2025/10/08 11:08

From version 1.21
edited by jadomatis
on 2025/09/29 14:02
Change comment: There is no comment for this version
To version 1.15
edited by jadomatis
on 2025/09/29 13:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -38,24 +38,4 @@
38 38  = Z-Axis Focusing =
39 39  
40 40  1. Place the workpiece/fixture in the work chamber and close the manual lift door.
41 -1. Use the automatic Z-axis to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height.
42 -1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual.
43 -
44 -
45 -
46 -= Parameter Verification =
47 -
48 -* Select a verified marking parameter set (power, speed, frequency, fill). Start with conservative energy to avoid burning or glare.
49 -* Ensure extraction is active to remove gases, vapors, aerosols, and dust during test marking.
50 -
51 -
52 -
53 -= First Test Mark =
54 -
55 -1. With the cabin closed and interlocks engaged, execute a short test mark on a sample of the target material.
56 -1. Observe quality and adjust parameters (e.g., reduce power/increase speed) as needed. Multiple repetitions may be used for depth, but monitor temperature to reduce fire risk.
57 -1. If unexpected behavior occurs, press STOP/EMERGENCY-STOP, investigate messages in Notifications, and correct the cause before resuming.
58 -
59 -
60 -
61 -
41 +1. Use the automatic Z-axis to set focus to the surface (per lens focal distance). Follow