... ... @@ -53,4 +53,12 @@
53 53  = First Test Mark =
54 54  
55 55  1. With the cabin closed and interlocks engaged, execute a short test mark on a sample of the target material.
56 -1. Observe quality and adjust paramete
56 +1. Observe quality and adjust parameters (e.g., reduce power/increase speed) as needed. Multiple repetitions may be used for depth, but monitor temperature to reduce fire risk.
57 +1. If unexpected behavior occurs, press STOP/EMERGENCY-STOP, investigate messages in Notifications, and correct the cause before resuming.
58 +
59 +
60 +
61 += Post-Test Verification =
62 +
63 +* Inspect the mark; check legibility/contrast. Clean light residue if necessary.
64 +* Re-check filters/airflow after