Last modified by jadomatis on 2025/10/08 11:08

From version 1.2
edited by jadomatis
on 2025/09/29 10:55
Change comment: There is no comment for this version
To version 1.9
edited by jadomatis
on 2025/09/29 12:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2,4 +2,17 @@
2 2  
3 3  Confirm the following before applying power:
4 4  
5 -* Electrical
5 +* Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF.
6 +* Protective housing and door interlocks are intact; laser viewing window shows now damage.
7 +* Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands.
8 +* Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport.
9 +* Airflow at 19" drawers is unobstructed; filter mats are clean to prevent heat build-up.
10 +* Operator is familiar with laser safety requirements; responsibilities are defined.
11 +Note: The Multi-Light contains a Class 4 source operated as Class 1 in the closed cabin. Never bypass safety devices.
12 +
13 +
14 +
15 += Electrical Start-Up =
16 +
17 +1. Connect the system to the specified mains supply. Ensure extraction is running.
18 +1. Set the mains switch to ON. Internal electronics initialize; status indicators light as described on the operator panel