Last modified by jadomatis on 2025/10/08 11:08

From version 1.18
edited by jadomatis
on 2025/09/29 13:23
Change comment: There is no comment for this version
To version 1.21
edited by jadomatis
on 2025/09/29 14:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -50,4 +50,12 @@
50 50  
51 51  
52 52  
53 -= =
53 += First Test Mark =
54 +
55 +1. With the cabin closed and interlocks engaged, execute a short test mark on a sample of the target material.
56 +1. Observe quality and adjust parameters (e.g., reduce power/increase speed) as needed. Multiple repetitions may be used for depth, but monitor temperature to reduce fire risk.
57 +1. If unexpected behavior occurs, press STOP/EMERGENCY-STOP, investigate messages in Notifications, and correct the cause before resuming.
58 +
59 +
60 +
61 +