... ... @@ -45,4 +45,20 @@
45 45  
46 46  = Parameter Verification =
47 47  
48 -* Select a verified marking parameter set (power, speed, frequency, fill). Start with conservative energy to a
48 +* Select a verified marking parameter set (power, speed, frequency, fill). Start with conservative energy to avoid burning or glare.
49 +* Ensure extraction is active to remove gases, vapors, aerosols, and dust during test marking.
50 +
51 +
52 +
53 += First Test Mark =
54 +
55 +1. With the cabin closed and interlocks engaged, execute a short test mark on a sample of the target material.
56 +1. Observe quality and adjust parameters (e.g., reduce power/increase speed) as needed. Multiple repetitions may be used for depth, but monitor temperature to reduce fire risk.
57 +1. If unexpected behavior occurs, press STOP/EMERGENCY-STOP, investigate messages in Notifications, and correct the cause before resuming.
58 +
59 +
60 +
61 += Post-Test Verification =
62 +
63 +* Inspect the mark; check legibility/contrast. Clean light residue if necessary.
64 +* Re-check filters/airflow after