Changes for page Commissioning and First Start-Up
Last modified by jadomatis on 2025/10/08 11:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,29 +20,4 @@ 20 20 21 21 22 22 23 -= Software and Device Connection = 24 - 25 -1. Launch the AnyMarker Designer software. 26 -1. Verify communication with the laser controller in the software (device connected, parameters readable). 27 -If connection fails, switch OFF, check cabling and restart. 28 - 29 - 30 - 31 -= Initial Checks With Pilot Laser = 32 - 33 -* Load or create a test layout in AnyMarker Designer. 34 -* Enable the pilot laser to project contours on the workpiece; verify orientation and placement without laser emission. Keep the door closed. 35 - 36 - 37 - 38 -= Z-Axis Focusing = 39 - 40 -1. Place the workpiece/fixture in the work chamber and close the manual lift door. 41 -1. Use the automatic Z-axis to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height. 42 -1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual. 43 - 44 - 45 - 46 -= Parameter Verification = 47 - 48 -* Select a verified marking parameter set (power, speed, frequency, fill). Start with conservative energy to a 23 +