Changes for page Commissioning and First Start-Up
Last modified by jadomatis on 2025/10/08 11:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,38 +1,87 @@ 1 +This procedure describes how to bring the Multi-Light workstation into operation safely after transport or installation. **Only qualified personnel **may commission the system. Observer all safety notes before switching on. 2 + 1 1 = Preconditions (Before Switching On) = 2 2 3 3 Confirm the following before applying power: 4 4 5 -* Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF. 6 -* Protective housing and door interlocks are intact; laser viewing window shows now damage. 7 -* Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands. 8 -* Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport. 9 -* Airflow at 19" drawers is unobstructed; filter mats are clean to prevent heat build-up. 10 -* Operator is familiar with laser safety requirements; responsibilities are defined. 11 -Note: The Multi-Light contains a Class 4 source operated as Class 1 in the closed cabin. Never bypass safety devices. 7 +* **Electrical installation is correct**; mains **voltage and frequency **match the rating place. Main switch is OFF. 8 +* **Protective housing** and **door interlocks** are intact; **laser viewing window** shows now damage. 9 +* **Optics are clean**; remove any **transport/lens cover** only now. Avoid touching optics with bare hands. 10 +* **Ambient conditions**: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport. 11 +* **Airflow **at 19" drawers is unobstructed; **filter mats** are clean to prevent heat build-up. 12 +* **Fume extraction **is installed and operational (mandatory for personnel safety and to protect optics). 13 +* Operator is familiar with **laser safety** requirements; responsibilities are defined. 14 +**Note**: The Multi-Light contains a **Class 4 **source operated as **Class 1** in the closed cabin. Never bypass safety devices. 12 12 13 13 14 14 15 15 = Electrical Start-Up = 16 16 17 -1. Connect the system to the specified mains supply. Ensure extraction is running. 18 -1. Set the mains switch to ON. Internal electronics initialize; status indicators light as described on the operator panel. 19 -1. Power on the control PC (or workstation) and peripherals needed for operation. 20 +1. Connect the system to the specified **mains supply**. Ensure extraction is running. 21 +1. Set the **mains switch to ON**. Internal electronics initialize; status indicators light as described on the operator panel. 22 +1. Power on the **control PC** (or workstation) and peripherals needed for operation. 20 20 21 21 22 22 23 23 = Software and Device Connection = 24 24 25 -1. Launch the AnyMarker Designer software. 26 -1. Verify communication with the laser controller in the software (device connected, parameters readable). 27 -If connection fails, switch OFF, check cabling and restart. 28 +1. Launch the **AnyMarker Designer **software. 29 +1. Verify communication with the **laser controller** in the software (device connected, parameters readable). 30 +If connection fails, switch **OFF**, check cabling and restart. 28 28 29 29 30 30 31 31 = Initial Checks With Pilot Laser = 32 32 33 -* Load or create a test layout in AnyMarker Designer. 34 -* Enable the pilot laser to project contours on the workpiece; verify orientation and placement without laser emission. Keep the door closed. 36 +* Load or create a **test layout** in AnyMarker Designer. 37 +* Enable the** pilot laser **to project contours on the workpiece; verify **orientation and placement** without laser emission. Keep the door closed. 35 35 36 36 37 37 41 += Z-Axis Focusing = 42 + 43 +1. Place the workpiece/fixture in the work chamber and close the **manual lift door**. 44 +1. Use the **automatic Z-axis** to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height. 45 +1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual. 46 + 47 + 48 + 49 += Parameter Verification = 50 + 51 +* Select a verified **marking parameter set** (power, speed, frequency, fill). Start with conservative energy to avoid burning or glare. 52 +* Ensure extraction is active to remove **gases**, **vapors**, **aerosols**, **and dust** during test marking. 53 + 54 + 55 + 56 += First Test Mark = 57 + 58 +1. With the cabin closed and interlocks engaged, execute a **short test mark** on a sample of the target material. 59 +1. Observe quality and adjust **parameters **(e.g., reduce power/increase speed) as needed. Multiple **repetitions **may be used for depth, but monitor temperature to reduce fire risk. 60 +1. If unexpected behavior occurs, press **STOP**/**EMERGENCY-STOP**, investigate messages in **Notifications**, and correct the cause before resuming. 61 + 62 + 63 + 64 += Post-Test Verification = 65 + 66 +* Inspect the mark; check legibility/contrast. Clean light residue if necessary. 67 +* Re-check **filters**/**airflow **after prolonged tests. Excess dust must not accumulate. 68 +* Document the **approved parameter set** for production. 69 + 70 + 71 + 72 += Normal Operation Handover = 73 + 74 +* Train operators on **door interlock**, **pilot laser**, **start**/**stop**, and **notifications **usage. 75 +* Emphasize daily** pre-shift checks **(visible damage, labels present, safety devices functional). 76 + 77 + 78 + 79 += Shutdown (End of Day) = 80 + 81 +1. Stop software and close the project. 82 +1. Turn the system **OFF **via main switch; power down extraction as specified. 83 +1. Clean the work area; never leave the machine **unattended **while powered. 84 + 85 + 86 + 38 38