Changes for page Commissioning and First Start-Up
Last modified by jadomatis on 2025/10/08 11:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -35,4 +35,22 @@ 35 35 36 36 37 37 38 - 38 += Z-Axis Focusing = 39 + 40 +1. Place the workpiece/fixture in the work chamber and close the manual lift door. 41 +1. Use the automatic Z-axis to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height. 42 +1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual. 43 + 44 + 45 + 46 += Parameter Verification = 47 + 48 +* Select a verified marking parameter set (power, speed, frequency, fill). Start with conservative energy to avoid burning or glare. 49 +* Ensure extraction is active to remove gases, vapors, aerosols, and dust during test marking. 50 + 51 + 52 + 53 += First Test Mark = 54 + 55 +1. With the cabin closed and interlocks engaged, execute a short test mark on a sample of the target material. 56 +1. Observe quality and adjust paramete