Last modified by jadomatis on 2025/10/08 11:08

From version 1.12
edited by jadomatis
on 2025/09/29 12:24
Change comment: There is no comment for this version
To version 1.17
edited by jadomatis
on 2025/09/29 13:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -28,4 +28,21 @@
28 28  
29 29  
30 30  
31 -
31 += Initial Checks With Pilot Laser =
32 +
33 +* Load or create a test layout in AnyMarker Designer.
34 +* Enable the pilot laser to project contours on the workpiece; verify orientation and placement without laser emission. Keep the door closed.
35 +
36 +
37 +
38 += Z-Axis Focusing =
39 +
40 +1. Place the workpiece/fixture in the work chamber and close the manual lift door.
41 +1. Use the automatic Z-axis to set focus to the surface (per lens focal distance). Follow the on-screen/readout guidance for focal height.
42 +1. Confirm best focus by pilot outline sharpness or focus gauge method recommended in the manual.
43 +
44 +
45 +
46 += Parameter Verification =
47 +
48 +* Select a verified marking parameter set (power, speed, frequency, fill). Start with conservative energy to a