Wiki source code of Commissioning and First Start-Up
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | = Preconditions (Before Switching On) = | ||
| 2 | |||
| 3 | Confirm the following before applying power: | ||
| 4 | |||
| 5 | * Electrical installation is correct; mains voltage and frequency match the rating place. Main switch is OFF. | ||
| 6 | * Protective housing and door interlocks are intact; laser viewing window shows now damage. | ||
| 7 | * Optics are clean; remove any transport/lens cover only now. Avoid touching optics with bare hands. | ||
| 8 | * Ambient conditions: +15C to +35C. RH <90% non condensing; system acclimatized if temperature changed during transport. | ||
| 9 | * Airflow at 19" drawers is unobstructed; filter mats are clean to prevent heat build-up. | ||
| 10 | * Operator is familiar with laser safety requirements; responsibilities are defined. | ||
| 11 | Note: The Multi-Light contains a Class 4 source operated as Class 1 in the closed cabin. Never bypass safety devices. | ||
| 12 | |||
| 13 | |||
| 14 | |||
| 15 | = Electrical Start-Up = | ||
| 16 | |||
| 17 | 1. Connect the system to the specified mains supply. Ensure extraction is running. | ||
| 18 | 1. Set the mains switch to ON. Internal electronics initialize; status indicators light as described on the operator panel. | ||
| 19 | 1. Power on the control PC (or workstation) and peripherals needed for operation. | ||
| 20 | |||
| 21 | |||
| 22 | |||
| 23 | = Software and Device Connection = | ||
| 24 | |||
| 25 | 1. Launch the AnyMarker Designer software. | ||
| 26 | 1. Verify communication with the laser controller in the software (device connected, parameters readable). | ||
| 27 | If connection fails, switch OFF, check cabling and restart. | ||
| 28 | |||
| 29 | |||
| 30 | |||
| 31 | = Initial Checks With Pilot Laser = | ||
| 32 | |||
| 33 | * Load or create a test layout in AnyMarker Designer. | ||
| 34 | * Enable the pilot laser to project contours on the workpiece; verify orientation and placement without laser emission. Keep the door closed. | ||
| 35 | |||
| 36 | |||
| 37 | |||
| 38 | = Z-Axis Focusing = | ||
| 39 | |||
| 40 | 1. Place the workpiece/fixture in the work chamber and close the manual lift door. | ||
| 41 | 1. Use the automatic Z-axis to set focus to the surface (per lens focal distance). Follow |