Last modified by jadomatis on 2026/09/04 07:55

From version 8.1
edited by jadomatis
on 2026/09/04 07:55
Change comment: There is no comment for this version
To version 7.1
edited by jadomatis
on 2026/09/04 07:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -5,14 +5,11 @@
5 5  (% class="box warningmessage" %)
6 6  (((
7 7  Laser Class 1 operation depends on the complete protective system. The door switches, laser-protection window, cladding panels, and sealing profile must all be present, intact, and effective. An indicator light alone is not proof that the machine is safe.
8 -
9 9  )))
10 10  
11 -(% class="wikigeneratedid" %)
10 +=
11 +High-Light System Overview =
12 12  
13 -
14 -= High-Light System Overview =
15 -
16 16  [[image:1788499943895-329.png]]
17 17  
18 18  The High-Light uses an automatic lifting door and an enclosed marking chamber. The cabinet image shows two emergency-stop buttons on the illustrated configuration, while Section 7.1.1 describes the emergency-stop switch on the operator panel. Treat the delivered machine as authoritative and record any configuration-specific differences.
... ... @@ -48,11 +48,9 @@
48 48  **Restart restriction: **Releasing or acknowledging the emergency stop must never cause an automatic marking cycle. Restart only through the normal controlled start procedure after the area has been checked.
49 49  )))
50 50  
51 -(% class="wikigeneratedid" %)
48 +=
49 +Protective Door and Safety Switches =
52 52  
53 -
54 -= Protective Door and Safety Switches =
55 -
56 56  Two safety switches monitor the closed position of the protective door. The High-Light cannot mark while the door is open. The positioning laser remains active, so the absence of marking radiation does not mean that every optical source is off.
57 57  
58 58  * Do not reach into the marking chamber while an automatic movement is possible.
... ... @@ -61,11 +61,9 @@
61 61  * If marking is possible with the door open, stop the system immediately and prevent further use.
62 62  * Do not adjust, bridge, tape, magnetically defeat, or otherwise manipulate either door switch.
63 63  
64 -(% class="wikigeneratedid" %)
59 +==
60 +Status Indicators and Acknowledgment ==
65 65  
66 -
67 -== Status Indicators and Acknowledgment ==
68 -
69 69  |**Indicator/control**|**Meaning**|**If the expected state is absent**
70 70  |Blue acknowledgment button|The system is waiting for acknowledgment when the button is illuminated.|A continuously illuminated button can indicate that the emergency stop has not been released.
71 71  |Green indicator|Remains illuminated after AnyMarker has connected to the laser and the system is ready.|The system may still be waiting for acknowledgment or communication may not be established.
... ... @@ -85,26 +85,20 @@
85 85  
86 86  The observation window is made from laser-protection material selected for the installed laser type. If it is cracked, deeply scratched, loose, discoloured, chemically damaged, or otherwise impaired, stop laser operation immediately and replace it with the approved matching component.
87 87  
88 -(% class="wikigeneratedid" %)
81 +==
82 +Cladding Panels ==
89 89  
90 -
91 -== Cladding Panels ==
92 -
93 93  The cabinet cladding forms part of the laser-protective enclosure. Every panel must be installed and firmly secured. Drilling, cutting, replacing fasteners with unsuitable parts, leaving service panels open, or making unapproved modifications can invalidate the protective laser class.
94 94  
95 -(% class="wikigeneratedid" %)
86 +==
87 +Sealing Profile ==
96 96  
97 -
98 -== Sealing Profile ==
99 -
100 100  The sealing profile must close the intended enclosure interfaces. If it is missing, detached, compressed beyond serviceability, torn, or otherwise damaged, do not operate the laser until it has been replaced with an intact approved profile.
101 101  
91 +=
92 +Pre-Operation Safety-Device Check =
102 102  
103 -= Pre-Operation Safety-Device Check =
104 -
105 -* (((
106 -Confirm that all cladding panels and service covers are installed and firmly secured.
107 -)))
94 +* Confirm that all cladding panels and service covers are installed and firmly secured.
108 108  * Inspect the laser-protection window and confirm that it is undamaged and suitable for the installed source.
109 109  * Inspect the sealing profile around the protective enclosure for gaps, tears, detachment, or missing sections.
110 110  * Confirm that the protective door travels freely, closes fully, and is detected by both safety switches.
... ... @@ -130,11 +130,9 @@
130 130  1. Contact Schilling Marking Systems or authorized service personnel if the cause is not an approved operator-level correction.
131 131  1. After repair, verify the protective door, safety pressure edge, both door switches, emergency stop, shutter response, enclosure, protection window, sealing profile, and status indicators before release for production.
132 132  
133 -(% class="wikigeneratedid" %)
120 +=
121 +Configuration and Documentation Control =
134 134  
135 -
136 -= Configuration and Documentation Control =
137 -
138 138  High-Light systems may use fiber/MOPA, UV, Nd:YVO4, or UKP sources. The protection window, source labels, extraction requirements, cooling arrangement, and service precautions must match the installed configuration. Do not copy a component specification or photograph from another High-Light variant without checking the as-built machine.
139 139  
140 140  |**Record**|**What to capture**|**Why it matters**