Last modified by jadomatis on 2026/09/04 07:55

From version 7.2
edited by jadomatis
on 2026/09/04 07:54
Change comment: There is no comment for this version
To version 7.1
edited by jadomatis
on 2026/09/04 07:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -5,14 +5,11 @@
5 5  (% class="box warningmessage" %)
6 6  (((
7 7  Laser Class 1 operation depends on the complete protective system. The door switches, laser-protection window, cladding panels, and sealing profile must all be present, intact, and effective. An indicator light alone is not proof that the machine is safe.
8 -
9 9  )))
10 10  
11 -(% class="wikigeneratedid" %)
10 +=
11 +High-Light System Overview =
12 12  
13 -
14 -= High-Light System Overview =
15 -
16 16  [[image:1788499943895-329.png]]
17 17  
18 18  The High-Light uses an automatic lifting door and an enclosed marking chamber. The cabinet image shows two emergency-stop buttons on the illustrated configuration, while Section 7.1.1 describes the emergency-stop switch on the operator panel. Treat the delivered machine as authoritative and record any configuration-specific differences.
... ... @@ -75,7 +75,6 @@
75 75  
76 76  
77 77  
78 -
79 79  = Laser-Containment Components =
80 80  
81 81  == Laser-Protection Window ==
... ... @@ -92,18 +92,10 @@
92 92  
93 93  The sealing profile must close the intended enclosure interfaces. If it is missing, detached, compressed beyond serviceability, torn, or otherwise damaged, do not operate the laser until it has been replaced with an intact approved profile.
94 94  
95 -(% class="wikigeneratedid" %)
91 +=
92 +Pre-Operation Safety-Device Check =
96 96  
97 -
98 -(% class="wikigeneratedid" %)
99 -
100 -
101 -
102 -= Pre-Operation Safety-Device Check =
103 -
104 -* (((
105 -Confirm that all cladding panels and service covers are installed and firmly secured.
106 -)))
94 +* Confirm that all cladding panels and service covers are installed and firmly secured.
107 107  * Inspect the laser-protection window and confirm that it is undamaged and suitable for the installed source.
108 108  * Inspect the sealing profile around the protective enclosure for gaps, tears, detachment, or missing sections.
109 109  * Confirm that the protective door travels freely, closes fully, and is detected by both safety switches.
... ... @@ -120,7 +120,6 @@
120 120  
121 121  
122 122  
123 -
124 124  = Response to a Safety-Device Fault =
125 125  
126 126  1. Stop the current operation and use the emergency stop if an immediate hazard exists.