Changes for page System Overview and Safety Device
Last modified by jadomatis on 2026/09/04 07:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -78,18 +78,15 @@ 78 78 79 79 The observation window is made from laser-protection material selected for the installed laser type. If it is cracked, deeply scratched, loose, discoloured, chemically damaged, or otherwise impaired, stop laser operation immediately and replace it with the approved matching component. 80 80 81 -== 82 -Cladding Panels == 81 +== Cladding Panels == 83 83 84 84 The cabinet cladding forms part of the laser-protective enclosure. Every panel must be installed and firmly secured. Drilling, cutting, replacing fasteners with unsuitable parts, leaving service panels open, or making unapproved modifications can invalidate the protective laser class. 85 85 86 -== 87 -Sealing Profile == 85 +== Sealing Profile == 88 88 89 89 The sealing profile must close the intended enclosure interfaces. If it is missing, detached, compressed beyond serviceability, torn, or otherwise damaged, do not operate the laser until it has been replaced with an intact approved profile. 90 90 91 -= 92 -Pre-Operation Safety-Device Check = 89 += Pre-Operation Safety-Device Check = 93 93 94 94 * Confirm that all cladding panels and service covers are installed and firmly secured. 95 95 * Inspect the laser-protection window and confirm that it is undamaged and suitable for the installed source. ... ... @@ -101,13 +101,9 @@ 101 101 * Confirm that extraction and any configuration-specific cooling are ready before enabling marking. 102 102 * Verify the expected indicator sequence without treating the indicators as a substitute for safeguard checks. 103 103 104 -(% class="box warningmessage" %) 105 -((( 106 -**!!!Stop operation: **Do not use the High-Light if any safeguard is missing, damaged, loose, bypassed, incorrectly adjusted, or unsuitable for the installed laser configuration.!!! 107 -))) 101 +**Stop operation: **Do not use the High-Light if any safeguard is missing, damaged, loose, bypassed, incorrectly adjusted, or unsuitable for the installed laser configuration. 108 108 109 109 110 - 111 111 = Response to a Safety-Device Fault = 112 112 113 113 1. Stop the current operation and use the emergency stop if an immediate hazard exists. ... ... @@ -117,8 +117,7 @@ 117 117 1. Contact Schilling Marking Systems or authorized service personnel if the cause is not an approved operator-level correction. 118 118 1. After repair, verify the protective door, safety pressure edge, both door switches, emergency stop, shutter response, enclosure, protection window, sealing profile, and status indicators before release for production. 119 119 120 -= 121 -Configuration and Documentation Control = 113 += Configuration and Documentation Control = 122 122 123 123 High-Light systems may use fiber/MOPA, UV, Nd:YVO4, or UKP sources. The protection window, source labels, extraction requirements, cooling arrangement, and service precautions must match the installed configuration. Do not copy a component specification or photograph from another High-Light variant without checking the as-built machine. 124 124 ... ... @@ -126,3 +126,5 @@ 126 126 |Safety-device photographs|Emergency-stop buttons, door closing area, accessible interlock locations, protection window, panels, and sealing profile|Preserves the as-built arrangement for training and inspection. 127 127 |Installed source|Source type, wavelength, output, pulse data, and serial number|Determines compatible protection, labels, extraction, and service controls. 128 128 |Functional test|Date, tester, emergency-stop result, door-interlock result, shutter response, and corrective actions|Demonstrates that safeguards were checked before production or after service. 121 + 122 +**Related article: **Use the separate System Labels and Warnings article for warning-symbol meanings, confirmed marking-head label positions, and label replacement requirements.