Last modified by jadomatis on 2026/09/04 07:55

From version 6.5
edited by jadomatis
on 2026/09/04 07:47
Change comment: There is no comment for this version
To version 6.6
edited by jadomatis
on 2026/09/04 07:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,11 +1,14 @@
1 1  **Description**: The High-Light combines a Class 4 marking source with an enclosed workstation designed for Laser Class 1 operation. Learn about the protective devices, what each one does, and the checks required before operation.
2 2  
3 +{{toc/}}
4 +
3 3  (% class="box warningmessage" %)
4 4  (((
5 5  Laser Class 1 operation depends on the complete protective system. The door switches, laser-protection window, cladding panels, and sealing profile must all be present, intact, and effective. An indicator light alone is not proof that the machine is safe.
6 6  )))
7 7  
8 -= High-Light System Overview =
10 +=
11 +High-Light System Overview =
9 9  
10 10  [[image:1788499943895-329.png]]
11 11  
... ... @@ -42,7 +42,8 @@
42 42  **Restart restriction: **Releasing or acknowledging the emergency stop must never cause an automatic marking cycle. Restart only through the normal controlled start procedure after the area has been checked.
43 43  )))
44 44  
45 -= Protective Door and Safety Switches =
48 +=
49 +Protective Door and Safety Switches =
46 46  
47 47  Two safety switches monitor the closed position of the protective door. The High-Light cannot mark while the door is open. The positioning laser remains active, so the absence of marking radiation does not mean that every optical source is off.
48 48  
... ... @@ -52,7 +52,8 @@
52 52  * If marking is possible with the door open, stop the system immediately and prevent further use.
53 53  * Do not adjust, bridge, tape, magnetically defeat, or otherwise manipulate either door switch.
54 54  
55 -== Status Indicators and Acknowledgment ==
59 +==
60 +Status Indicators and Acknowledgment ==
56 56  
57 57  |**Indicator/control**|**Meaning**|**If the expected state is absent**
58 58  |Blue acknowledgment button|The system is waiting for acknowledgment when the button is illuminated.|A continuously illuminated button can indicate that the emergency stop has not been released.
... ... @@ -60,7 +60,10 @@
60 60  |Yellow indicator|Protective door is completely closed.|Open the door, inspect the closing area, and confirm that it closes completely. Do not force or bypass the switches.
61 61  |Red indicator|Marking is in progress.|If marking cannot start, check for an active emergency stop and confirm that the protective door is closed.
62 62  
68 +(% class="box infomessage" %)
69 +(((
63 63  **Indicator limitation: **Status LEDs assist operation and troubleshooting. They do not replace a visual inspection, an interlock test, or confirmation that the enclosure is intact.
71 +)))
64 64  
65 65  
66 66