... ... @@ -1,10 +1,16 @@
1 -The High-Light combines a Class 4 marking source with an enclosed workstation designed for Laser Class 1 operation. This article identifies the protective devices, explains what each one does, and defines the checks required before operation.
1 +**Description**: The High-Light combines a Class 4 marking source with an enclosed workstation designed for Laser Class 1 operation. Learn about the protective devices, what each one does, and the checks required before operation.
2 2  
3 +{{toc/}}
4 +
3 3  (% class="box warningmessage" %)
4 4  (((
5 5  Laser Class 1 operation depends on the complete protective system. The door switches, laser-protection window, cladding panels, and sealing profile must all be present, intact, and effective. An indicator light alone is not proof that the machine is safe.
8 +
6 6  )))
7 7  
11 +(% class="wikigeneratedid" %)
12 +
13 +
8 8  = High-Light System Overview =
9 9  
10 10  [[image:1788499943895-329.png]]
... ... @@ -18,7 +18,7 @@
18 18  |Main switch|Controls the electrical supply for normal start and shutdown.|Must be accessible and in the correct position. Do not use the emergency stop as a substitute for electrical isolation.
19 19  |Emergency-stop button|Immediately switches off the circuit, interrupts the laser beam through the shutter, stops all motion, and generates a fault message.|Must be released and functional before operation.
20 20  |Two protective-door safety switches|Monitor the closed position of the protective door. Marking is prevented while the door is open.|Both switches and the door closing function must be effective.
21 -|Safety pressure edge|Pressure-sensitive edge on the automatic lifting door can . The supplied manual does not define its exact stop or reversal response.|Must be unobstructed, intact, and function-tested according to the machine acceptance or service procedure.
27 +|Safety pressure edge|Pressure-sensitive edge that can be found on the automatic lifting door.|Must be unobstructed, intact, and function-tested according to the machine acceptance or service procedure.
22 22  |Laser-protection window|Allows observation while absorbing radiation from the installed laser type.|Must be undamaged and matched to the installed source.
23 23  |Cladding panels|Form part of the laser-protective enclosure.|All panels must be installed, firmly secured, and unmodified.
24 24  |Sealing profile|Closes enclosure gaps that could compromise laser containment.|Must be present and undamaged.
... ... @@ -42,6 +42,9 @@
42 42  **Restart restriction: **Releasing or acknowledging the emergency stop must never cause an automatic marking cycle. Restart only through the normal controlled start procedure after the area has been checked.
43 43  )))
44 44  
51 +(% class="wikigeneratedid" %)
52 +
53 +
45 45  = Protective Door and Safety Switches =
46 46  
47 47  Two safety switches monitor the closed position of the protective door. The High-Light cannot mark while the door is open. The positioning laser remains active, so the absence of marking radiation does not mean that every optical source is off.
... ... @@ -52,6 +52,9 @@
52 52  * If marking is possible with the door open, stop the system immediately and prevent further use.
53 53  * Do not adjust, bridge, tape, magnetically defeat, or otherwise manipulate either door switch.
54 54  
64 +(% class="wikigeneratedid" %)
65 +
66 +
55 55  == Status Indicators and Acknowledgment ==
56 56  
57 57  |**Indicator/control**|**Meaning**|**If the expected state is absent**
... ... @@ -60,7 +60,10 @@
60 60  |Yellow indicator|Protective door is completely closed.|Open the door, inspect the closing area, and confirm that it closes completely. Do not force or bypass the switches.
61 61  |Red indicator|Marking is in progress.|If marking cannot start, check for an active emergency stop and confirm that the protective door is closed.
62 62  
75 +(% class="box infomessage" %)
76 +(((
63 63  **Indicator limitation: **Status LEDs assist operation and troubleshooting. They do not replace a visual inspection, an interlock test, or confirmation that the enclosure is intact.
78 +)))
64 64  
65 65  
66 66  
... ... @@ -70,17 +70,26 @@
70 70  
71 71  The observation window is made from laser-protection material selected for the installed laser type. If it is cracked, deeply scratched, loose, discoloured, chemically damaged, or otherwise impaired, stop laser operation immediately and replace it with the approved matching component.
72 72  
88 +(% class="wikigeneratedid" %)
89 +
90 +
73 73  == Cladding Panels ==
74 74  
75 75  The cabinet cladding forms part of the laser-protective enclosure. Every panel must be installed and firmly secured. Drilling, cutting, replacing fasteners with unsuitable parts, leaving service panels open, or making unapproved modifications can invalidate the protective laser class.
76 76  
95 +(% class="wikigeneratedid" %)
96 +
97 +
77 77  == Sealing Profile ==
78 78  
79 79  The sealing profile must close the intended enclosure interfaces. If it is missing, detached, compressed beyond serviceability, torn, or otherwise damaged, do not operate the laser until it has been replaced with an intact approved profile.
80 80  
102 +
81 81  = Pre-Operation Safety-Device Check =
82 82  
83 -* Confirm that all cladding panels and service covers are installed and firmly secured.
105 +* (((
106 +Confirm that all cladding panels and service covers are installed and firmly secured.
107 +)))
84 84  * Inspect the laser-protection window and confirm that it is undamaged and suitable for the installed source.
85 85  * Inspect the sealing profile around the protective enclosure for gaps, tears, detachment, or missing sections.
86 86  * Confirm that the protective door travels freely, closes fully, and is detected by both safety switches.
... ... @@ -90,9 +90,13 @@
90 90  * Confirm that extraction and any configuration-specific cooling are ready before enabling marking.
91 91  * Verify the expected indicator sequence without treating the indicators as a substitute for safeguard checks.
92 92  
93 -**Stop operation: **Do not use the High-Light if any safeguard is missing, damaged, loose, bypassed, incorrectly adjusted, or unsuitable for the installed laser configuration.
117 +(% class="box warningmessage" %)
118 +(((
119 +**!!!Stop operation: **Do not use the High-Light if any safeguard is missing, damaged, loose, bypassed, incorrectly adjusted, or unsuitable for the installed laser configuration.!!!
120 +)))
94 94  
95 95  
123 +
96 96  = Response to a Safety-Device Fault =
97 97  
98 98  1. Stop the current operation and use the emergency stop if an immediate hazard exists.
... ... @@ -102,6 +102,9 @@
102 102  1. Contact Schilling Marking Systems or authorized service personnel if the cause is not an approved operator-level correction.
103 103  1. After repair, verify the protective door, safety pressure edge, both door switches, emergency stop, shutter response, enclosure, protection window, sealing profile, and status indicators before release for production.
104 104  
133 +(% class="wikigeneratedid" %)
134 +
135 +
105 105  = Configuration and Documentation Control =
106 106  
107 107  High-Light systems may use fiber/MOPA, UV, Nd:YVO4, or UKP sources. The protection window, source labels, extraction requirements, cooling arrangement, and service precautions must match the installed configuration. Do not copy a component specification or photograph from another High-Light variant without checking the as-built machine.
... ... @@ -110,5 +110,3 @@
110 110  |Safety-device photographs|Emergency-stop buttons, door closing area, accessible interlock locations, protection window, panels, and sealing profile|Preserves the as-built arrangement for training and inspection.
111 111  |Installed source|Source type, wavelength, output, pulse data, and serial number|Determines compatible protection, labels, extraction, and service controls.
112 112  |Functional test|Date, tester, emergency-stop result, door-interlock result, shutter response, and corrective actions|Demonstrates that safeguards were checked before production or after service.
113 -
114 -**Related article: **Use the separate System Labels and Warnings article for warning-symbol meanings, confirmed marking-head label positions, and label replacement requirements.