... ... @@ -1,4 +1,4 @@
1 -The High-Light combines a Class 4 marking source with an enclosed workstation designed for Laser Class 1 operation. This article identifies the protective devices, explains what each one does, and defines the checks required before operation.
1 +**Description**: The High-Light combines a Class 4 marking source with an enclosed workstation designed for Laser Class 1 operation. Learn about the protective devices, what each one does, and the checks required before operation.
2 2  
3 3  (% class="box warningmessage" %)
4 4  (((
... ... @@ -18,7 +18,7 @@
18 18  |Main switch|Controls the electrical supply for normal start and shutdown.|Must be accessible and in the correct position. Do not use the emergency stop as a substitute for electrical isolation.
19 19  |Emergency-stop button|Immediately switches off the circuit, interrupts the laser beam through the shutter, stops all motion, and generates a fault message.|Must be released and functional before operation.
20 20  |Two protective-door safety switches|Monitor the closed position of the protective door. Marking is prevented while the door is open.|Both switches and the door closing function must be effective.
21 -|Safety pressure edge|Pressure-sensitive edge on the automatic lifting door can . The supplied manual does not define its exact stop or reversal response.|Must be unobstructed, intact, and function-tested according to the machine acceptance or service procedure.
21 +|Safety pressure edge|Pressure-sensitive edge that can be found on the automatic lifting door.|Must be unobstructed, intact, and function-tested according to the machine acceptance or service procedure.
22 22  |Laser-protection window|Allows observation while absorbing radiation from the installed laser type.|Must be undamaged and matched to the installed source.
23 23  |Cladding panels|Form part of the laser-protective enclosure.|All panels must be installed, firmly secured, and unmodified.
24 24  |Sealing profile|Closes enclosure gaps that could compromise laser containment.|Must be present and undamaged.