... ... @@ -14,11 +14,11 @@
14 14  
15 15  = Protective Devices and Their Functions =
16 16  
17 -|**Protective device**|**Function**|**Required condition**
17 +|**Protective device**|**Function stated or implied by the manual**|**Required condition**
18 18  |Main switch|Controls the electrical supply for normal start and shutdown.|Must be accessible and in the correct position. Do not use the emergency stop as a substitute for electrical isolation.
19 19  |Emergency-stop button|Immediately switches off the circuit, interrupts the laser beam through the shutter, stops all motion, and generates a fault message.|Must be released and functional before operation.
20 20  |Two protective-door safety switches|Monitor the closed position of the protective door. Marking is prevented while the door is open.|Both switches and the door closing function must be effective.
21 -|Safety pressure edge|Pressure-sensitive edge on the automatic lifting door can . The supplied manual does not define its exact stop or reversal response.|Must be unobstructed, intact, and function-tested according to the machine acceptance or service procedure.
21 +|Safety pressure edge|The cabinet overview identifies a pressure-sensitive edge on the automatic lifting door. The supplied manual does not define its exact stop or reversal response.|Must be unobstructed, intact, and function-tested according to the machine acceptance or service procedure.
22 22  |Laser-protection window|Allows observation while absorbing radiation from the installed laser type.|Must be undamaged and matched to the installed source.
23 23  |Cladding panels|Form part of the laser-protective enclosure.|All panels must be installed, firmly secured, and unmodified.
24 24  |Sealing profile|Closes enclosure gaps that could compromise laser containment.|Must be present and undamaged.
... ... @@ -54,7 +54,7 @@
54 54  
55 55  == Status Indicators and Acknowledgment ==
56 56  
57 -|**Indicator/control**|**Meaning**|**If the expected state is absent**
57 +|**Indicator/control**|**Meanin**|**If the expected state is absent**
58 58  |Blue acknowledgment button|The system is waiting for acknowledgment when the button is illuminated.|A continuously illuminated button can indicate that the emergency stop has not been released.
59 59  |Green indicator|Remains illuminated after AnyMarker has connected to the laser and the system is ready.|The system may still be waiting for acknowledgment or communication may not be established.
60 60  |Yellow indicator|Protective door is completely closed.|Open the door, inspect the closing area, and confirm that it closes completely. Do not force or bypass the switches.