Last modified by jadomatis on 2026/09/04 07:55

From version 6.2
edited by jadomatis
on 2026/09/04 07:42
Change comment: There is no comment for this version
To version 6.5
edited by jadomatis
on 2026/09/04 07:47
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,23 +1,24 @@
1 -The High-Light combines a Class 4 marking source with an enclosed workstation designed for Laser Class 1 operation. This article identifies the protective devices, explains what each one does, and defines the checks required before operation.
1 +**Description**: The High-Light combines a Class 4 marking source with an enclosed workstation designed for Laser Class 1 operation. Learn about the protective devices, what each one does, and the checks required before operation.
2 2  
3 -**Safety basis: **Laser Class 1 operation depends on the complete protective system. The door switches, laser-protection window, cladding panels, and sealing profile must all be present, intact, and effective. An indicator light alone is not proof that the machine is safe.
3 +(% class="box warningmessage" %)
4 +(((
5 +Laser Class 1 operation depends on the complete protective system. The door switches, laser-protection window, cladding panels, and sealing profile must all be present, intact, and effective. An indicator light alone is not proof that the machine is safe.
6 +)))
4 4  
5 5  = High-Light System Overview =
6 6  
7 7  [[image:1788499943895-329.png]]
8 8  
9 -
10 10  The High-Light uses an automatic lifting door and an enclosed marking chamber. The cabinet image shows two emergency-stop buttons on the illustrated configuration, while Section 7.1.1 describes the emergency-stop switch on the operator panel. Treat the delivered machine as authoritative and record any configuration-specific differences.
11 11  
12 12  
13 -
14 14  = Protective Devices and Their Functions =
15 15  
16 -|**Protective device**|**Function stated or implied by the manual**|**Required condition**
17 +|**Protective device**|**Function**|**Required condition**
17 17  |Main switch|Controls the electrical supply for normal start and shutdown.|Must be accessible and in the correct position. Do not use the emergency stop as a substitute for electrical isolation.
18 18  |Emergency-stop button|Immediately switches off the circuit, interrupts the laser beam through the shutter, stops all motion, and generates a fault message.|Must be released and functional before operation.
19 19  |Two protective-door safety switches|Monitor the closed position of the protective door. Marking is prevented while the door is open.|Both switches and the door closing function must be effective.
20 -|Safety pressure edge|The cabinet overview identifies a pressure-sensitive edge on the automatic lifting door. The supplied manual does not define its exact stop or reversal response.|Must be unobstructed, intact, and function-tested according to the machine acceptance or service procedure.
21 +|Safety pressure edge|Pressure-sensitive edge that can be found on the automatic lifting door.|Must be unobstructed, intact, and function-tested according to the machine acceptance or service procedure.
21 21  |Laser-protection window|Allows observation while absorbing radiation from the installed laser type.|Must be undamaged and matched to the installed source.
22 22  |Cladding panels|Form part of the laser-protective enclosure.|All panels must be installed, firmly secured, and unmodified.
23 23  |Sealing profile|Closes enclosure gaps that could compromise laser containment.|Must be present and undamaged.
... ... @@ -36,7 +36,10 @@
36 36  * Inspect the door, enclosure, work area, and moving axes before acknowledging the fault and restarting.
37 37  * For maintenance or electrical work, follow the required power-isolation procedure; the emergency stop is not an isolation device.
38 38  
40 +(% class="box warningmessage" %)
41 +(((
39 39  **Restart restriction: **Releasing or acknowledging the emergency stop must never cause an automatic marking cycle. Restart only through the normal controlled start procedure after the area has been checked.
43 +)))
40 40  
41 41  = Protective Door and Safety Switches =
42 42  
... ... @@ -50,7 +50,7 @@
50 50  
51 51  == Status Indicators and Acknowledgment ==
52 52  
53 -|**Indicator/control**|**Normal meaning described by the manual**|**If the expected state is absent**
57 +|**Indicator/control**|**Meaning**|**If the expected state is absent**
54 54  |Blue acknowledgment button|The system is waiting for acknowledgment when the button is illuminated.|A continuously illuminated button can indicate that the emergency stop has not been released.
55 55  |Green indicator|Remains illuminated after AnyMarker has connected to the laser and the system is ready.|The system may still be waiting for acknowledgment or communication may not be established.
56 56  |Yellow indicator|Protective door is completely closed.|Open the door, inspect the closing area, and confirm that it closes completely. Do not force or bypass the switches.