... ... @@ -26,7 +26,7 @@
26 26  
27 27  = Confirmed Physical Labels on the Marking Head =
28 28  
29 -Section 5.5 photographs two labels on the lower front face of the marking-head housing. Figure 3 replaces the German label wording with numbered English translation overlays; the approved labels on the delivered machine remain authoritative.
29 +Section 5.5 photographs two labels on the lower front face of the marking-head housing. . Figure 3 replaces the German label wording with numbered English translation overlays; the approved labels on the delivered machine remain authoritative.
30 30  
31 31  [[image:1788414118893-138.png]]
32 32  
... ... @@ -50,7 +50,7 @@
50 50  
51 51  = Laser Classes and Source-Specific Data =
52 52  
53 -|**Item**|**Classification**|**Meaning**
53 +|**Item**|**Classification stated by the manual**|**Meaning**
54 54  |Complete High-Light workstation|Laser Class 1 during normal enclosed operation|The protective enclosure prevents access to hazardous marking radiation when intact and correctly closed.
55 55  |Internal marking source|Laser Class 4 when accessible|Accessible radiation is hazardous to the eyes and skin; diffuse radiation may also be hazardous and can create fire or explosion risks.
56 56  |Positioning/focusing laser|Laser Class 2|Visible positioning beam; do not stare into the beam.
... ... @@ -62,12 +62,12 @@
62 62  
63 63  == Wavelengths Listed for High-Light Configurations ==
64 64  
65 -|**Configuration**|**Data**|**Documentation requirement**
65 +|**Configuration**|**Manual data**|**Documentation requirement**
66 66  |Fiber / MOPA|1060-1070 nm|The technical-data table prints the unit as 'mm'; the context indicates this is an apparent unit error. Verify the as-built source and its permanent label.
67 67  |Nd:YVO4 safety example|1064 nm|The safety narrative describes an invisible 1064 nm source. Do not apply this value automatically to every High-Light configuration.
68 68  |UV|355 nm|Use UV-specific source, label, and protection information.
69 69  |UKP picosecond|1030 nm; 1-5 ps|Use label and protection information matching the installed ultrashort-pulse source.
70 -|Positioning/focus|Visible Class 2 beam|The exact wavelength is not stated
70 +|Positioning/focus|Visible Class 2 beam|The exact wavelength is not stated in the supplied manual.
71 71  
72 72  (% class="box infomessage" %)
73 73  (((
... ... @@ -82,7 +82,7 @@
82 82  
83 83  [[image:1788414118900-957.png]]
84 84  
85 -* Appoint a trained laser safety officer where required by applicable regulations such  BGV B 2.
85 +* Appoint a trained laser safety officer where required by applicable regulations; the manual cites BGV B 2.
86 86  * Mark the hazard area externally with warning lights and warning signs.
87 87  * Secure the hazard area against unauthorized entry.
88 88  * Wear laser-protective eyewear matched to the wavelength and output of the accessible source.