Last modified by jadomatis on 2026/09/02 13:07

From version 1.7
edited by jadomatis
on 2026/09/02 10:54
Change comment: There is no comment for this version
To version 2.1
edited by jadomatis
on 2026/09/02 13:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -25,4 +25,145 @@
25 25  
26 26  == Extraction Filters ==
27 27  
28 -When an ext
28 +When an extraction system is installed, its filters must be checked and replaced according to the process load and filter condition.
29 +
30 +* Check the pre-filter at least monthly.
31 +* Replace the pre-filter when it is fully or heavily contaminated.
32 +* Check the main filter at least annually.
33 +* Replace the main filter when contaminated or when extraction performance decreases.
34 +
35 +Processes that produce large quantities of dust, fumes, or aerosols may require more frequent filter replacement.
36 +
37 +(% class="box warningmessage" %)
38 +(((
39 +**Important**: Used extraction filters may contain hazardous process residues, Handle and dispose of them according to the processed material and applicable local requirements.
40 +)))
41 +
42 +== Optical Cleaning Materials ==
43 +
44 +Only suitable optical-cleaning materials may be used on laser lenses and protective glass.
45 +
46 +Approved cleaning materials may include:
47 +
48 +* Soft, lint-free optical cloths
49 +* Lens-cleaning paper
50 +* Optical lens-cleaning wipes
51 +* A small manual air blower
52 +* A manufacturer-approved optical cleaning solution
53 +* High-purity alcohol of at least 98%, where approved
54 +
55 +Never use:
56 +
57 +* Compressed air
58 +* Paper towels or abrasive cloths
59 +* Hard tools or scraping instruments
60 +* Contaminated cleaning cloths
61 +* Household glass cleaners
62 +* Unapproved solvents
63 +
64 +Apply the cleaning solution to the cloth rather than dipping the cloth into the solution
65 +
66 +For complete cleaning instructions, refer to the **[[High-Light Maintenance Article>>doc:Schilling Marking Systems High-Light.Getting Started.Maintenance.WebHome]]**.
67 +
68 +
69 +== Lubricants ==
70 +
71 +The Z-axis spindle should be inspected monthly and cleaned and lubricated when required.
72 +
73 +Use only a lubricant approved for the installed axis. Do not allow oil or grease to contact optical components, workpieces, electrical parts, or marking surfaces.
74 +
75 +
76 +== Laser Foil ==
77 +
78 +Laser foil is used to produce high-contrast markings on suitable metal surfaces. Its compatibility must be validated with the installed laser source, material, focus, and marking parameters.
79 +
80 +
81 +== Ablation Film ==
82 +
83 +Ablation film can be marked and cut using a validated laser process before being bonded to the workpiece. Different film colors and material properties may be available.
84 +
85 +For more information, refer to[[ **Accessories and Options**>>doc:Schilling Marking Systems High-Light.Overview.Accessories and Options.WebHome]].
86 +
87 +
88 += Replacement And Service Parts =
89 +
90 +Some High-Light components influence laser containment, electrical safety, or machine accuracy. These components must only be replaced by Schilling Marking Systems or authorized personnel.
91 +
92 +Safety-critical and service components may include:
93 +
94 +* Laser-protection windows
95 +* Protective objective glass
96 +* Objective and optical components
97 +* Door safety switches and interlocks
98 +* Emergency-stop components
99 +* Enclosure sealing profiles
100 +* Laser-protection brushes
101 +* Cable-entry protection components
102 +* Axis components and drive assemblies
103 +* Cooling fans
104 +* Laser-source components
105 +* Electrical and control components
106 +* Computer hardware
107 +
108 +(% class="box warningmessage" %)
109 +(((
110 +Damage to the protective enclosure, laser-protection window, sealing profiles, brushes, door interlocks, or cable entries may invalidate Laser Class 1 protection. Stop using the system and contact Schilling Marking Systems immediately.
111 +)))
112 +
113 += Ordering Spare Parts =
114 +
115 +Provide the following information when requesting spare parts or consumables:
116 +
117 +* Machine designation: High-Light
118 +* Machine serial number
119 +* Year of manufacture
120 +* Installed laser source and output power
121 +* Laser wavelength
122 +* Description of the required component
123 +* Component location
124 +* Required quantity
125 +* Photographs of the components, where useful
126 +* Details of any visible damage or error
127 +* Installed accessory configuration, where relevant
128 +
129 +For objectives, protective glass, filters, and optical components, also provide the installed lens or marking-field configuration.
130 +
131 +Do not select an optical component only because it physically fits. Fiber/MOPA, UV, and ultrashort-pulse configurations may require different wavelength-specific optics.
132 +
133 +
134 += Replacing Components =
135 +
136 +Before replacing an operator-serviceable component:
137 +
138 +1. Finish the current marking process.
139 +1. Remove the workpiece.
140 +1. Shut down the laser computer correctly.
141 +1. Switch off the High-Light.
142 +1. Disconnect the electrical supply where required.
143 +1. Verify that the system is de-energized.
144 +1. Follow the applicable maintenance instructions.
145 +1. Install only the approved replacement component.
146 +1. Check that all guards and covers have been correctly reinstalled.
147 +1. Test the system before returning it to production.
148 +
149 +
150 +
151 += Storage =
152 +
153 +Make sure that spare parts and consumables are stored:
154 +
155 +* In a clean and dry environment
156 +* In their original packaging
157 +* Away from dust, moisture, chemicals, and direct sunlight
158 +* Protected against impact and scratching
159 +* Clearly identified for the correct High-Light configuration
160 +* According to the applicable safety data sheet, where chemicals are involved
161 +
162 +Optical components should remain sealed until they are required.
163 +
164 +
165 += Service Support =
166 +
167 +If a laser source or another major component requires repair, contact Schilling Marking Systems before removing or replacing it.
168 +
169 +A temporary replacement laser or contract-marking service may be available during the repair period, subject to availability and agreement with Schilling Marking Systems.