Changes for page Spare Parts and Consumables
Last modified by jadomatis on 2026/09/02 13:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,4 +16,154 @@ 16 16 17 17 Filter mats protect the laser source, electronics, and computer components against dust and contamination in the cooling air. 18 18 19 -* 19 +* Inspect the ventilation area monthly. 20 +* Replace heavily contaminated filter mats. 21 +* Do not operate the system when airflow is restricted. 22 +* Use the correct filter material and dimensions for the installed High-Light configuration 23 + 24 + 25 + 26 +== Extraction Filters == 27 + 28 +When an extraction system is installed, its filters must be checked and replaced according to the process load and filter condition. 29 + 30 +* Check the pre-filter at least monthly. 31 +* Replace the pre-filter when it is fully or heavily contaminated. 32 +* Check the main filter at least annually. 33 +* Replace the main filter when contaminated or when extraction performance decreases. 34 + 35 +Processes that produce large quantities of dust, fumes, or aerosols may require more frequent filter replacement. 36 + 37 +(% class="box warningmessage" %) 38 +((( 39 +**Important**: Used extraction filters may contain hazardous process residues, Handle and dispose of them according to the processed material and applicable local requirements. 40 +))) 41 + 42 +== Optical Cleaning Materials == 43 + 44 +Only suitable optical-cleaning materials may be used on laser lenses and protective glass. 45 + 46 +Approved cleaning materials may include: 47 + 48 +* Soft, lint-free optical cloths 49 +* Lens-cleaning paper 50 +* Optical lens-cleaning wipes 51 +* A small manual air blower 52 +* A manufacturer-approved optical cleaning solution 53 +* High-purity alcohol of at least 98%, where approved 54 + 55 +Never use: 56 + 57 +* Compressed air 58 +* Paper towels or abrasive cloths 59 +* Hard tools or scraping instruments 60 +* Contaminated cleaning cloths 61 +* Household glass cleaners 62 +* Unapproved solvents 63 + 64 +Apply the cleaning solution to the cloth rather than dipping the cloth into the solution 65 + 66 +For complete cleaning instructions, refer to the **[[High-Light Maintenance Article>>doc:Schilling Marking Systems High-Light.Getting Started.Maintenance.WebHome]]**. 67 + 68 + 69 +== Lubricants == 70 + 71 +The Z-axis spindle should be inspected monthly and cleaned and lubricated when required. 72 + 73 +Use only a lubricant approved for the installed axis. Do not allow oil or grease to contact optical components, workpieces, electrical parts, or marking surfaces. 74 + 75 + 76 +== Laser Foil == 77 + 78 +Laser foil is used to produce high-contrast markings on suitable metal surfaces. Its compatibility must be validated with the installed laser source, material, focus, and marking parameters. 79 + 80 + 81 +== Ablation Film == 82 + 83 +Ablation film can be marked and cut using a validated laser process before being bonded to the workpiece. Different film colors and material properties may be available. 84 + 85 +For more information, refer to[[ **Accessories and Options**>>doc:Schilling Marking Systems High-Light.Overview.Accessories and Options.WebHome]]. 86 + 87 + 88 += Replacement And Service Parts = 89 + 90 +Some High-Light components influence laser containment, electrical safety, or machine accuracy. These components must only be replaced by Schilling Marking Systems or authorized personnel. 91 + 92 +Safety-critical and service components may include: 93 + 94 +* Laser-protection windows 95 +* Protective objective glass 96 +* Objective and optical components 97 +* Door safety switches and interlocks 98 +* Emergency-stop components 99 +* Enclosure sealing profiles 100 +* Laser-protection brushes 101 +* Cable-entry protection components 102 +* Axis components and drive assemblies 103 +* Cooling fans 104 +* Laser-source components 105 +* Electrical and control components 106 +* Computer hardware 107 + 108 +(% class="box warningmessage" %) 109 +((( 110 +Damage to the protective enclosure, laser-protection window, sealing profiles, brushes, door interlocks, or cable entries may invalidate Laser Class 1 protection. Stop using the system and contact Schilling Marking Systems immediately. 111 +))) 112 + 113 += Ordering Spare Parts = 114 + 115 +Provide the following information when requesting spare parts or consumables: 116 + 117 +* Machine designation: High-Light 118 +* Machine serial number 119 +* Year of manufacture 120 +* Installed laser source and output power 121 +* Laser wavelength 122 +* Description of the required component 123 +* Component location 124 +* Required quantity 125 +* Photographs of the components, where useful 126 +* Details of any visible damage or error 127 +* Installed accessory configuration, where relevant 128 + 129 +For objectives, protective glass, filters, and optical components, also provide the installed lens or marking-field configuration. 130 + 131 +Do not select an optical component only because it physically fits. Fiber/MOPA, UV, and ultrashort-pulse configurations may require different wavelength-specific optics. 132 + 133 + 134 += Replacing Components = 135 + 136 +Before replacing an operator-serviceable component: 137 + 138 +1. Finish the current marking process. 139 +1. Remove the workpiece. 140 +1. Shut down the laser computer correctly. 141 +1. Switch off the High-Light. 142 +1. Disconnect the electrical supply where required. 143 +1. Verify that the system is de-energized. 144 +1. Follow the applicable maintenance instructions. 145 +1. Install only the approved replacement component. 146 +1. Check that all guards and covers have been correctly reinstalled. 147 +1. Test the system before returning it to production. 148 + 149 + 150 + 151 += Storage = 152 + 153 +Make sure that spare parts and consumables are stored: 154 + 155 +* In a clean and dry environment 156 +* In their original packaging 157 +* Away from dust, moisture, chemicals, and direct sunlight 158 +* Protected against impact and scratching 159 +* Clearly identified for the correct High-Light configuration 160 +* According to the applicable safety data sheet, where chemicals are involved 161 + 162 +Optical components should remain sealed until they are required. 163 + 164 + 165 += Service Support = 166 + 167 +If a laser source or another major component requires repair, contact Schilling Marking Systems before removing or replacing it. 168 + 169 +A temporary replacement laser or contract-marking service may be available during the repair period, subject to availability and agreement with Schilling Marking Systems.